4.6 Article

4D-flow cardiac magnetic resonance imaging after aortic root replacement with long-valved decellularized aortic homografts: comparison to valve-sparing aortic root replacement and healthy controls

Journal

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
Volume 61, Issue 6, Pages 1307-1315

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezac016

Keywords

Aortic valve disease; Haemodynamics; 4D flow; Decellularized homograft; Aortic root replacement

Funding

  1. European Union's HORIZON 2020 Programme [643597]
  2. H2020 Societal Challenges Programme [643597] Funding Source: H2020 Societal Challenges Programme

Ask authors/readers for more resources

This study compares the hemodynamic parameters of long-valved decellularized aortic homografts and patients who underwent valve-sparing aortic root replacement with healthy controls. The results show that the hemodynamic parameters of decellularized long aortic homografts are similar to those of healthy controls and patients who underwent valve-sparing aortic root replacement 2.5 years postoperatively.
OBJECTIVES Long-valved decellularized aortic homografts (DAH) may be used in young patients to treat aortic valve disease associated with aortic root dilatation, thereby eliminating the need for prosthetic material and anticoagulation. METHODS Thirty-three male subjects in 3 equally sized cohorts were compared: patients following DAH implantation with a median age of 29 years [interquartile range (IQR) 27.5-37.5], patients post-valve-sparing aortic root replacement (VSARR), median 44 years (IQR 31.5-49) and healthy controls, median 33 years (IQR 28-40, P = 0.228). Time-resolved three-dimensional phase-contrast cardiac magnetic resonance imaging was performed to assess maximum blood flow velocity, pulse wave velocity, mechanical energy loss (EL), wall shear stress and flow patterns (vorticity, eccentricity, helicity) in 5 different planes of the aorta. RESULTS The mean time between surgery and cardiovascular magnetic resonance was 2.56 +/- 2.0 years in DAH vs 2.67 +/- 2.1 in VSARR, P = 0.500. No significant differences in maximum velocity and pulse wave velocity were found between healthy controls and DAH across all planes. Velocity in the proximal aorta was significantly higher in VSARR (182.91 +/- 53.91 cm/s, P = 0.032) compared with healthy controls. EL was significantly higher in VSARR in the proximal aorta with 1.85 mW (IQR 1.39-2.95) compared with healthy controls, 1.06 mW (0.91-1.22, P = 0.016), as well as in the entire thoracic aorta. In contrast, there was no significant EL in DAH in the proximal, 1.27 m/W (0.92-1.53, P = 0.296), as well as in the thoracic aorta, 7.7 m/W (5.25-9.90, P = 0.114), compared with healthy controls. There were no significant differences in wall shear stress parameters for all 5 regions of the thoracic aorta between the 3 groups. DAH patients, however, showed more vorticity, helicity and eccentricity in the ascending aorta compared with healthy controls (P < 0.019). CONCLUSIONS Decellularized long aortic homografts exhibit near to normal haemodynamic parameters 2.5 years postoperatively compared with healthy controls and VSARR.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available