4.5 Article

Effects of aerosol particle size on the measurement of airborne PM2.5 with a low-cost particulate matter sensor (LCPMS) in a laboratory chamber

Journal

ENVIRONMENTAL MONITORING AND ASSESSMENT
Volume 194, Issue 2, Pages -

Publisher

SPRINGER
DOI: 10.1007/s10661-021-09715-6

Keywords

Low-cost sensors; Particulate matter (PM); PM sensor calibration; Particle size

Funding

  1. Centers for Disease Control and Prevention/National Institute of Occupational Safety and Health [T42OH008421]
  2. Southwest Center for Occupational and Environmental Health (SWCOEH)
  3. National Institute of Environmental Health Sciences [R21ES031795, P30ES030285]

Ask authors/readers for more resources

This study examined the linear relationship and agreement between low-cost particulate matter sensors (LCPMS) and research grade particulate matter (PM) monitors. Results showed that the particle size bins of PM affected the linear relationship, with larger particles having a higher slope and larger error in converted mass concentration.
Previous validation studies found a good linear correlation between the low-cost particulate matter sensors (LCPMS) and other research grade particulate matter (PM) monitors. This study aimed to determine if different particle size bins of PM would affect the linear relationship and agreement between the Dylos DC1700 (LCPMS) particle count measurements (converted to PM2.5 mass concentrations) and the Grimm 11R (research grade instrument) mass concentration measurements. Three size groups of PM2.5 (mass median aerodynamic diameters (MMAD): < 1 mu m, 1-2 mu m, and > 2 mu m) were generated inside a laboratory chamber, controlled for temperature and relative humidity, by dispersing sodium chloride crystals through a nebulizer. A linear regression comparing 1-min average PM2.5 particle counts from the Dylos DC1700 (Dylos) to the Grimm 11R (Grimm) mass concentrations was estimated by particle size group. The slope for the linear regression was found to increase as MMAD increased (< 1 mu m, 0.75 (R-2 = 0.95); 1-2 mu m, 0.90 (R-2 = 0.93); and > 2 mu m, 1.03 (R-2 = 0.94). The linear slopes were used to convert Dylos counts to mass concentration, and the agreement between converted Dylos mass and Grimm mass was estimated. The absolute relative error between converted Dylos mass and the Grimm mass was smaller in the < 1 mu m group (16%) and 1-2 mu m group (16%) compared to the > 2 mu m group (32%). Therefore, the bias between converted Dylos mass and Grimm mass varied by size group. Future studies examining particle size bins over a wider range of coarse particles (> 2.5 mu m) would provide useful information for accurately converting LCPMS counts to mass concentration.