4.7 Article

A passive evaporative cooling heat sink method for enhancing low-grade waste heat recovery capacity of thermoelectric generators

Journal

ENERGY CONVERSION AND MANAGEMENT
Volume 251, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2021.114931

Keywords

Passive evaporative cooling; Thermoelectric generator; Waste heat recovery; TEG performance improvement

Funding

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Science, ICT & Future Planning [NRF-2016R1C1B2012136]

Ask authors/readers for more resources

This study utilized a novel PECHS to enhance the waste heat recovery capacity of a TEG, establishing a theoretical model to analyze the effects of key parameters on the TEG output capacity. The results indicated that the output capacity is positively correlated with T-H and L-f, while inversely correlated with RH, T-amb, and t(f). Additionally, the impact of increasing L-f on the cooling capability of the PECHS and the influence of RH on the TEG output capacity were discussed.
In this study, we utilized a novel passive evaporative cooling heat sink (PECHS) to enhance the waste heat recovery capacity of a thermoelectric generator (TEG). When heat is applied to the PECHS placed across the TEG, convection heat dissipation and evaporative cooling occur on the fins, thus, greatly improving the TEG output capacity. We established a theoretical model of the PECHS cooled TEG, and investigated the effects of certain key parameters on the TEG output capacity. The results show that the TEG output capacity is positively correlated with the TEG hot side temperature (T-H) and fin height (L-f), and inversely correlated with the ambient relative humidity (RH), ambient temperature (T-amb), and fin thickness (t(f)). However, as L-f increases, the rate of increase in the cooling capability of the PECHS decreases. Moreover, RH has a small impact on the TEG output capacity. Considering the heat dissipation capacity and cost, a PECHS needs to have an optimized number of fins (M). Consequently, the TEG open-circuit voltage (U-open = 4.86 V) and maximum output power (P-max = 4.1 W) were obtained under fixed conditions (T-H = 150 degrees C, RH = 50%, T-amb = 20 degrees C, L-f = 35 mm, t(f) = 1 mm, M = 11). The results show that the U-open and P-max are 1.83 and 3.33 times of a normal heat sink case (U-open = 2.66 V and P-max = 1.23 W), respectively. The theoretical model was verified using the constructed experimental system. Our findings show that PECHS is an efficient passive cooling device and can potentially be used in cooling applications such as photovoltaic board cooling and building cooling.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available