4.8 Article

Resolving local reaction environment toward an optimized CO2-to-CO conversion performance

Journal

ENERGY & ENVIRONMENTAL SCIENCE
Volume 15, Issue 2, Pages 749-759

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1ee02966e

Keywords

-

Funding

  1. National Natural Science Foundation of China (NSFC) [22002088]
  2. Shanghai Sailing Program [20YF1420500]
  3. Oceanic Interdisciplinary Program of Shanghai Jiao Tong University [SL2020MS007]

Ask authors/readers for more resources

The local reaction environment, especially the electrode-electrolyte interface near the cathode, plays a crucial role in defining the activity and selectivity of the electrochemical CO2 reduction reaction. A differential electrochemical mass spectroscopy approach on the Ag electrode was used to investigate this, leading to insights for optimized CO2-to-CO conversion performance. A multi-physics model with computational fluid dynamics and chemical simulation demonstrated the flow pattern and CO2 distribution, while spectroelectrochemical method investigated promotion effects on Ag catalyzed CO2 reduction.
The local reaction environment, especially the electrode-electrolyte interface and the relevant hydrodynamic boundary layer in the vicinity of the cathode, plays a vital role in defining the activity and selectivity of the electrochemical CO2 reduction reaction. Here, we present a differential electrochemical mass spectroscopic (DEMS) approach on the Ag electrode to resolve this information and provide hints for optimized CO2-to-CO conversion performance. A multi-physics model with computational fluid dynamics and chemical simulation is firstly proposed to demonstrate the flow pattern and the CO2 distribution within the cathodic DEMS chamber under operational conditions. Using this developed spectroelectrochemical method, we investigate the promotion effects of CO2 mass transport, cation identity and surface topology on Ag catalyzed CO2 reduction at a temporal resolution of similar to 200 ms. As a proof of concept, these fundamental understandings have been validated in a pilot anion exchange membrane electrolyzer, leading to a CO partial current density above 650 mA cm(-2) at 4.0 V, an operational voltage window wider than 1.0 V and a stable CO generation for 100 hours at 500 mA cm(-2) for CO selectivity above 80%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available