4.5 Review

Optimal Control Method of Variable Air Volume Terminal Unit System

Journal

ENERGIES
Volume 14, Issue 22, Pages -

Publisher

MDPI
DOI: 10.3390/en14227527

Keywords

variable air volume system; terminal unit; optimal control; prediction model; sensor calibration

Categories

Funding

  1. National Research Foundation of Korea (NRF) - Korea government [NRF-2019R1A2C1009445]

Ask authors/readers for more resources

The study reviewed types, control methods, prediction models, and sensor calibration methods of variable air volume (VAV) terminal units. Analysis of the existing research revealed the importance of control methods, mathematical models, and sensor calibration techniques in improving the efficiency of VAV systems.
This study reviewed the existing studies on the types of variable air volume (VAV) terminal units, control and operation methods, prediction models, and sensor calibration methods. As a result of analyzing the existing research trends on the system type, characteristics, and control method of VAV terminal units studies such as theoretical verification and energy simulation were conducted to improve the existing control methods, reset the set value using a mathematical model, and add a monitoring sensor for the application of control methods. The mathematical model used in the study of VAV terminal unit control methods was used to derive set values for minimum air volume, supply temperature, ventilation requirements, and indoor comfort. The mathematical model has a limitation in collecting input information for professional knowledge and model development, and development of a building environment prediction model using a black box model is being studied. The VAV terminal unit system uses a sensor to control the device, and when an error occurs in the sensor, indoor comfort problems and energy waste occur. To solve this problem, sensor calibration techniques have been developed using statistical models, mathematical models, and Bayesian statistical models. The possibility of developing a method for calibrating the variable air volume terminal unit sensor using the prediction model was confirmed. In conclusion, the VAV terminal unit system is one of the most energy efficient systems. The energy saving potential of current VAV systems can still be improved through control methods, the use of predictive models, and sensor calibration methods.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available