4.7 Article

A computational optimization study of a self-expandable transcatheter aortic valve

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Finite element analysis of transcatheter aortic valve implantation: Insights on the modelling of self-expandable devices

Alice Finotello et al.

Summary: This study focuses on calibrating Nitinol constitutive parameters of four self-expandable devices and conducting patient-specific simulations to investigate the impact of metallic frame parameters choice on simulation results.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2021)

Article Engineering, Biomedical

Performance of high conformability vs. high radial force devices in the virtual treatment of TAVI patients with bicuspid aortic valve

Alice Finotello et al.

Summary: This study compared the performance of devices featuring high conformability (HC) against those with high radial force (HRF) in TAVI procedures for patients with bicuspid aortic valve (BAV). The results showed that HRF devices had better outcomes in BAV anatomies, particularly in reducing paravalvular area and increasing stent-root contact area.

MEDICAL ENGINEERING & PHYSICS (2021)

Article Computer Science, Interdisciplinary Applications

In silico biomechanical design of the metal frame of transcatheter aortic valves: multi-objective shape and cross-sectional size optimization

Dario Carbonaro et al.

Summary: This study presents a computational framework for optimizing the shape and cross-sectional size of TAV frames, aiming to improve the mechanical performance of the device. By utilizing finite element analyses and surrogate modeling, optimized TAV frame designs were successfully identified, leading to enhanced procedural outcomes and reduced development costs.

STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION (2021)

Article Computer Science, Interdisciplinary Applications

Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve

Salvatore Pasta et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2020)

Article Cardiac & Cardiovascular Systems

Bioprosthetic Aortic Valve Leaflet Thickening in the Evolut Low Risk Sub-Study

Philipp Blanke et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2020)

Article Cardiac & Cardiovascular Systems

Stent and leaflet stresses in 26-mm, third-generation, balloon-expandable transcatheter aortic valve

Yue Xuan et al.

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY (2019)

Article Computer Science, Interdisciplinary Applications

Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts

Narendra Kurnia Putra et al.

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING (2019)

Article Medicine, General & Internal

Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients

M. J. Mack et al.

NEW ENGLAND JOURNAL OF MEDICINE (2019)

Article Medicine, General & Internal

Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients

Jeffrey J. Popma et al.

NEW ENGLAND JOURNAL OF MEDICINE (2019)

Article Cardiac & Cardiovascular Systems

Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation

Giorgia Rocatello et al.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2019)

Article Cardiac & Cardiovascular Systems

On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid-Structure Interaction Approach

Giulia Luraghi et al.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2019)

Review Medicine, General & Internal

Transcatheter aortic valve implantation: Update in 2018

Nils Perrin et al.

EUROPEAN JOURNAL OF INTERNAL MEDICINE (2018)

Article Engineering, Biomedical

Surrogate-based visualization and sensitivity analysis of coronary stent performance: A study on the influence of geometric design

Nelson S. Ribeiro et al.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2018)

Article Cardiac & Cardiovascular Systems

Early Outcomes With the Evolut PRO Repositionable Self-Expanding Transcatheter Aortic Valve With Pericardial Wrap

John K. Forrest et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2018)

Article Engineering, Biomedical

Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium

Maria Sol Cabrera et al.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2017)

Article Engineering, Biomedical

Multi-objective optimization of nitinol stent design

G. Alaimo et al.

MEDICAL ENGINEERING & PHYSICS (2017)

Article Engineering, Biomedical

The role of inelastic deformations in the mechanical response of endovascular shape memory alloy devices

Lorenza Petrini et al.

PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE (2017)

Article Engineering, Biomedical

Multi-objective optimization of coronary stent using Kriging surrogate model

Hongxia Li et al.

BIOMEDICAL ENGINEERING ONLINE (2016)

Review Peripheral Vascular Disease

Transcatheter Aortic Valve Implantation

S. Chris Malaisrie et al.

CURRENT ATHEROSCLEROSIS REPORTS (2016)

Article Materials Science, Multidisciplinary

Multiobjective robust optimization of coronary stents

Sriram Tammareddi et al.

MATERIALS & DESIGN (2016)

Article Cardiac & Cardiovascular Systems

Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics

Wenbin Mao et al.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2016)

Article Engineering, Biomedical

Computational Modeling to Predict Fatigue Behavior of NiTi Stents: What Do We Need?

Elena Dordoni et al.

JOURNAL OF FUNCTIONAL BIOMATERIALS (2015)

Article Cardiac & Cardiovascular Systems

Transcatheter aortic valve implantation: status and challenges

Gregory A. Fishbein et al.

CARDIOVASCULAR PATHOLOGY (2014)

Article Materials Science, Multidisciplinary

Parametrical optimization of stent design; a numerical-based approach

Amirmostafa Amirjani et al.

COMPUTATIONAL MATERIALS SCIENCE (2014)

Article Medicine, General & Internal

Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis

David H. Adams et al.

NEW ENGLAND JOURNAL OF MEDICINE (2014)

Review Cardiac & Cardiovascular Systems

Transcatheter aortic valve implantation (TAVI): Valve design and evolution

Jonathon P. Fanning et al.

INTERNATIONAL JOURNAL OF CARDIOLOGY (2013)

Article Biophysics

Shape optimization of stress concentration-free lattice for self-expandable Nitinol stent-grafts

Ehsan Masoumi Khalil Abad et al.

JOURNAL OF BIOMECHANICS (2012)

Review Cardiac & Cardiovascular Systems

Transcatheter aortic valve implantation: current and future approaches

Josep Rodes-Cabau

NATURE REVIEWS CARDIOLOGY (2012)

Article Engineering, Biomedical

Multiobjective design optimisation of coronary stents

Sanjay Pant et al.

BIOMATERIALS (2011)

Review Computer Science, Interdisciplinary Applications

Survey of modeling and optimization strategies to solve high-dimensional design problems with computationally-expensive black-box functions

Songqing Shan et al.

STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION (2010)

Article Biophysics

Computational mechanics of Nitinol stent grafts

C. Kleinstreuer et al.

JOURNAL OF BIOMECHANICS (2008)

Article Engineering, Biomedical

Fatigue and durability of Nitinol stents

A. R. Pelton et al.

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2008)

Article Engineering, Biomedical

A predictive study of the mechanical behaviour of coronary stents by computer modelling

F Migliavacca et al.

MEDICAL ENGINEERING & PHYSICS (2005)

Article Surgery

An overview of superelastic stent design

TW Duerig et al.

MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES (2000)