4.6 Article Proceedings Paper

Epileptogenic Source Imaging Using Cross-Frequency Coupled Signals From Scalp EEG

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 63, Issue 12, Pages 2607-2618

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2016.2613936

Keywords

Artifactual immunity; cross-frequency coupling; epilepsy; EEG source imaging (ESI); modulation index (MI)

Funding

  1. Natural Sciences and Engineering Research Council of Canada
  2. Canadian Institutes of Health Research
  3. China Scholarship Council

Ask authors/readers for more resources

Objective: The epileptogenic zone (EZ) is a brain region containing the sources of seizure genesis. Removal of the EZ is associated with cessation of seizures after resective surgical procedures, as measured by Engel Class I score. This study describes a novel EEG (electroencephalography) source imaging (ESI) method which uses cross-frequency coupled potential signals (SCFC) derived from scalp EEG. Methods: Scalp EEG were recorded from ten patients (20 seizures) suffering from epilepsy. The SCFC were constructed from the phase and amplitude of the lower and higher frequency rhythms at electrographic seizure onset. ESI was then performed using the SCFC. Validation of the technique was facilitated by forward and inverse computer modeling of known cortical sources, and the correspondence of the ESI with EZ in resected regions of patients. Results: For ten seizures sampled at or above 500 Hz from four patients, all estimated sources lay within the resected region, emphasizing the clinical importance of higher sampling rates. The SCFC demonstrated significant advantages over the raw scalp EEG, indicating its robust noise performance. Modeling investigations indicated that a signal-to-noise ratio above 0.2 was sufficient to achieve successful localization regarding EMG artifacts. Conclusion: The association of the estimated sources to the EZ suggests that cross-frequency coupling is a feature of the brain's neural networks, not of artifactual activity. The SCFC can effectively extract brain signals from a noisy background. Significance: We propose this approach to enhance the placement of intracranial electrode for surgical intervention.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available