4.5 Article

Acupoint Injection Decreases Anesthetic Cosumption during Combined Spinal-Epidural and Patient-Controlled Epidural Labor Analgesia

Journal

CHINESE JOURNAL OF INTEGRATIVE MEDICINE
Volume 28, Issue 3, Pages 257-262

Publisher

SPRINGER
DOI: 10.1007/s11655-021-3501-8

Keywords

acupoint injection; combined spinal-epidural analgesia; labor analgesia; anesthetic consumption; multimodal analgesia

Funding

  1. Guangdong Science and Technology Department of China [2016A020226051]

Ask authors/readers for more resources

The study demonstrated that acupoint injection combined with CSEA plus PCEA for labor analgesia can reduce anesthetic consumption, improve analgesic quality, and decrease adverse reactions in parturients.
Objective To explore if acupoint injection can improve analgesic effects or delivery outcomes in parturients who received combined spinal-epidural analgesia (CSEA) and patient-controlled epidural analgesia (PCEA) for labor analgesia. Methods A total of 307 participants were prospectively collected from July 2017 to December 2019. The participants were randomized into the combined acupoint injection with CSEA plus PCEA group (AICP group, n=168) and CSEA plus PCEA group (CP group, n=139) for labor analgesia using a random number table. Both groups received CSEA plus PCEA at cervical dilation 3 cm during labor process, and parturients of the AICP group were implemented acupoint injection for which bilateral acupoint of Zusanli (ST 36) and Sanyinjiao (SP 6) were selected in addition. The primary outcome was Visual Analogue Scale (VAS) score, and the secondary outcomes were obstetric outcomes and requirement of anesthetics doses. Safety evaluations were performed after intervention. Results The VAS scores were significantly lower in the AICP group than in the CP group at 10, 30, 60, and 120 min after labor analgesia (all P<0.05). The latent phase of the AICP group was shorter than that of the CP group (P<0.05). There were less additional anesthetics consumption, lower incidences of uterine atony, fever, pruritus and urinary retention in the AICP group than those in the CP group (all P<0.05). Conclusion Acupoint injection combined CSEA plus PCEA for labor analgesia can decrease the anesthetic consumption, improve analgesic quality, and reduce adverse reactions in the parturients. (Registration No. ChiMCTR-2000003120)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available