4.7 Article

Lung Response to a Higher Positive End-Expiratory Pressure in Mechanically Ventilated Patients With COVID-19

Journal

CHEST
Volume 161, Issue 4, Pages 979-988

Publisher

ELSEVIER
DOI: 10.1016/j.chest.2021.10.012

Keywords

acute respiratory distress syndrome; coronavirus disease 2019; mechanical ventilation; positive end-expiratory pressure

Ask authors/readers for more resources

Patients with early ARDS due to COVID-19 have a large potential for lung recruitment, but their compliance and Pa-CO2 may not improve with higher PEEP, possibly due to hyperinflation.
BACKGROUND: International guidelines suggest using a higher (> 10 cm H2O) positive end expiratory pressure (PEEP) in patients with moderate-to-severe ARDS due to COVID-19. However, even if oxygenation generally improves with a higher PEEP, compliance, and Pa(CO2 )frequently do not, as if recruitment was small. RESEARCH QUESTION: Is the potential for lung recruitment small in patients with early ARDS due to COVID-19? STUDY DESIGN AND METHODS: Forty patients with ARDS due to COVID-19 were studied in the supine position within 3 days of endotracheal intubation. They all underwent a PEEP trial, in which oxygenation, compliance, and Pa-CO2 were measured with 5, 10, and 15 cm H2O of PEEP, and all other ventilatory settings unchanged. Twenty underwent a whole-lung static CT scan at 5 and 45 cm H2O, and the other 20 at 5 and 15 cm H2O of airway pressure. Recruitment and hyperinflation were defined as a decrease in the volume of the non-aerated (density above -100 HU) and an increase in the volume of the over-aerated (density below -900 HU) lung compartments, respectively. RESULTS: From 5 to 15 cm H2O, oxygenation improved in 36 (90%) patients but compliance only in 11 (28%) and Paco(2) only in 14 (35%). From 5 to 45 cm H2O, recruitment was 351 (161-462) mL and hyperinflation 465 (220-681) mL. From 5 to 15 cm H2O, recruitment was 168 (110-202) mL and hyperinflation 121 (63-270) mL. Hyperinflation variably developed in all patients and exceeded recruitment in more than half of them. INTERPRETATION: Patients with early ARDS due to COVID-19, ventilated in the supine position, present with a large potential for lung recruitment. Even so, their compliance and Pa-CO2 do not generally improve with a higher PEEP, possibly because of hyperinflation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available