4.6 Article

Bubble/micro-bubble regime transition in a pressurized bubble column of a low surface tension liquid system

Journal

CHEMICAL ENGINEERING SCIENCE
Volume 249, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ces.2021.117191

Keywords

Pressurized bubble column; Single nozzle; Micro-bubbles; Regime transition; Low surface tension liquid

Funding

  1. National Research Council of Science & Technology (NST) - Ministry of Science and ICT (MSIT) , Republic of Korea [CRC-14-1-KRICT]

Ask authors/readers for more resources

The study aimed to quantitatively analyze the transition point of bubble/micro-bubble regime in a bubble column. It found that as gas velocity at the orifice increased, the sizes of bubbles falling apart from the nozzle also increased, along with an increase in standard deviation of differential pressure. Bubbles grew until they fell from the tip of the jet under certain conditions.
The objective of this study was to quantitatively analyze bubble/micro-bubble regime transition point in a bubble column. A test was carried out with a cylindrical stainless-steel column having an inner diameter of 0.097 m and a height of 1.8 m. An air was injected as a gas medium. Kerosene with a density of 800 kg/m(3), viscosity of 1.64 x 10(-3) Pa.s, and surface tension of 23 x 10(-3) N/m at 20 +/- 2 degrees C was used as a liquid. The experiment was conducted on a single nozzle plate with different hole sizes (0.7, 1.5, 2.0, and 3.46 mm). To analyze the standard deviation of the differential pressure signal by air bubbles separated from the jet, 12,000 differential pressure data from 0.05 m to 0.15 m of height were measured at 200 Hz under each condition. As gas velocity at the orifice increased, sizes of bubbles falling apart from the nozzle increased. Standard deviation of differential pressure also increased. Bubbles grew until they fell from the tip of the jet. At higher orifice gas velocity, the standard deviation of the differential pressure was reduced due to the occurrence of micro-bubbles. Since the standard deviation of the differential pressure showed a high peak at We/Re-g(-8) = 1.2 x 10(45) for all cases, this value was selected as a demarcation of bubble/heterogeneous micro-bubble regime transition. The standard deviation of pressure drop fluctuation was the lowest at We/Re-g(-8) = 6.0 x 10(48). This point was determined as the homogeneous micro-bubble regime point. (C) 2021 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available