4.7 Article

A self-powered biosensor for glucose detection using modified pencil graphite electrodes as transducers

Journal

CHEMICAL ENGINEERING JOURNAL
Volume 426, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2021.131835

Keywords

PQQ-dependent glucose dehydrogenase; Bilirubin oxidase; Pencil graphite electrodes; Self-powered biosensor; Microenergy production; Biofuel cell

Funding

  1. FEDER funds through the POCI [UIDB/50006/2020, UIDP/50006/2020, PTDC/ASP-PES/29547/2017 (POCI-01-0145-FEDER-029547PTDC/ASP-PES/29547/2017, POCI-01-0145-FEDER-029547]
  2. FCT-Foundation for Science and Technology

Ask authors/readers for more resources

Biofuel cells can be used as self-powered biosensors for glucose detection, achieving low detection limits and long-term stability.
Biofuel cells are an interesting way of microenergy production that can be advantageously channeled for biosensing applications. In this study, a biofuel cell was developed and applied as a self-powered biosensor for glucose detection. Glucose oxidase was initially tested for the bioanode and, since no evidence of direct electron transfer was observed in the absence of the co-substrate, it was not further considered. The enzymes Pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQGDH) and Bilirubin oxidase (BOx) were immobilized on Pencil graphite electrodes (PGE), previously nanostructured with MWCNT, serving as bioanode and biocathode, respectively. The bifunctional crosslinker 1-pyrenebutanoic acid succinimidyl ester (PBSE) was used as a simple but efficient tethering agent, enabling the establishment of direct electron transfer events. Cyclic and linear sweep voltammetry, and amperometry were employed for individual characterization of bioanode and biocathode as biosensors for the respective enzymatic substrates. A mean sensitivity of 77.7 +/- 5.9 mu A cm-2 mM-1 was obtained for glucose with a Limit of detection (LOD) of 4.0 +/- 2.2 mu M, whereas in the detection of O2, the sensitivity and LOD achieved were 336 +/- 22 mu A cm-2 mM-1 and 3.2 +/- 1.0 mu M, respectively. Finally, the PQQGDH bioanode and BOx biocathode were conjugated into a biofuel cell and further characterized as a selfpowered biosensor for glucose, exhibiting a linear range up to 1 mM, an excellent sensitivity of 8.08 mu W cm-2 mM- 1, a low LOD of 0.084 mM and long stability (94% of the original response after 12 days). Therefore, PGE transducers and PBSE are valuable strategies for the design of simple and efficient self-powered biosensors.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available