4.8 Article

All-sealed paper-based electrochemiluminescence platform for on-site determination of lead ions

Journal

BIOSENSORS & BIOELECTRONICS
Volume 192, Issue -, Pages -

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113524

Keywords

Lab-on-paper; Plastic package; Electrochemiluminescence; Lead ions; Pt

Funding

  1. National Natural Science Foundation of China [21874055, 21904047]
  2. Taishan Scholars Program
  3. Case-by-Case Project for Top Outstanding Talents of Jinan
  4. project of 20 items of University of Jinan [2018GXRC001]

Ask authors/readers for more resources

An all-sealed paper-based electrochemiluminescence platform was developed for sensitive analysis of lead ions, combining convenient plastic packaging technology. The platform achieved wide linear relationship and low detection limit for rapid detection of heavy metal ions, showing promise for on-site contamination analysis in the future.
Lab-on-paper (LOP) devices are urgently required for the rapid development of point-of-care diagnoses and environmental assays. Herein, an all-sealed paper-based electrochemiluminescence (ECL) platform was developed to achieve lead ions (Pb2+) sensitive analysis via incorporating convenient plastic package technology. Benefiting from transparent plastic encapsulation, the sealed devices effectively avoided the interference of O2. Meanwhile, myrica rubra-like Pt nanomaterials (MPNs) prepared by an economical and easy-to-operate ultrasound method were employed to catalyze H2O2 decomposition. With the help of Pb2+-specific DNAzymes, the oligonucleotide probe functionalized via MPNs could be detached from the device in the presence of target, resulting in the reduced ECL intensity. Moreover, the combination of modified paper electrode with functional regions separated by multiple layers of wax enhanced the practicability of the LOP device for rapid detection. Under the optimal conditions, the all-sealed platform achieved wide linear relationship ranging from 0.01 nM to 0.05 mu M with a low detection limit of 0.004 nM for sensitive detecting Pb2+. It is believed that this platform could provide a robust, simple and versatile strategy for sensitive determination of heavy metal ions, and be applied in on-site contamination analysis in the future.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available