4.8 Article

Power quality assessment using signal periodicity independent algorithms-A shipboard microgrid case study

Journal

APPLIED ENERGY
Volume 307, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2021.118151

Keywords

Shipboard microgrids; Discrete Fourier Transform (DFT); Energy quality assessment; Fast Fourier Transform (FFT); Harmonic analysis; Eigenvalue solution; Singular value decomposition

Funding

  1. VILLUM FONDEN under the VILLUM Investigator Grant [25920]
  2. Center for Research on Microgrids (CROM) [MOST 110-2221-E-992-044-MY3]
  3. Ministry of Science and Technology of Taiwan

Ask authors/readers for more resources

This paper proposes two developed open-loop algorithms for assessing the harmonics distortion of shipboard microgrids. These algorithms provide fast transient response and accurate analysis without relying on signal periodicity or frequency information. The algorithms are suitable for both short-term protective action and long-term preventive action stages.
Retrofitting of shipboard microgrids is receiving much attention nowadays due to the flexibility it offers to adapt existing ships with rapid market variations to move towards all-electric ships (A-ESs). This modernity mainly relies on incorporating the power electronics converters that unfortunately draw a large number of harmonics, which affect the energy quality and threaten the system stability and crew/passengers safety. The contribution of this paper lies in proposing two developed open-loop algorithms to assess the harmonics distortion of A-ESs without relying on signal periodicity. The first algorithm is an offline-based analyzing technique developed for the short-term protective action stage, which incorporates the eigenvalue solution inside the short-time fast Fourier transform (ST-FFT) to adapt its window size. Consequently, this algorithm can provide a comprehensive harmonics analysis with a fast transient response even under large system frequency drifts. The second algorithm is an online-based assessing technique, which is very suitable for the long-term preventive action stage to provide accurate harmonics distortion assessment with the fast transient response and efficient computation burden. This approach relies on cascading three moving average filters (MAFs) with particular window sizes to filter and estimate the mean value inside the discrete Fourier transform and the true RMS blocks without the need of frequency information. Hence, it results in enhancing the harmonics rejection capability of the algorithm even under the existence of non-characteristic harmonics and frequency drifts. Simulation and experimental results are provided to validate the efficacy of the proposed algorithms and the results are compared with traditional methods.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.