Bipolar Electrode Array for Multiplexed Detection of Prostate Cancer Biomarkers

Journal

ANALYTICAL CHEMISTRY
Volume 94, Issue 6, Pages 3005-3012

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c05383

Keywords

-

Funding

  1. National Key R&D Program of China [2016YFA0201200]
  2. National Natural Science Foundation of China [22034003]
  3. Excellent Research Program of Nanjing University [ZYJH004]

Ask authors/readers for more resources

This study presents a microfluidic BPE array chip for multiplex detection of cancer biomarkers. The chip successfully controls the direction of liquid flow through a special channel structure and different sizes of channels with varying flow resistances, enabling rapid and automatic multiplex sampling. The chip exhibits good reproducibility and high sensitivity, and shows excellent performance in real sample analysis.
Owing to the characteristics of high throughput, high flexibility, and convenient separation of the sensing and reporting reactions, the bipolar electrode (BPE) shows great potential in clinical analysis. However, there are some difficulties in the combination of BPEs and multiplex electrochemiluminescence (ECL) biosensing, such as the need for small sample consumption, multistep operations, and separated sample loading. In this paper, a microfluidic BPE array chip was fabricated toward multiplex detection of cancer biomarkers. With a special channel structure and the difference in flow resistance of channels of different sizes, the direction of liquid flow was successfully controlled. In this way, rapid and automatic multiplex sampling was achieved on the array, which would help improve the sensing efficiency and reduce the reagent consumption. The ECL BPE array chip served as an immunosensor for multiple prostate cancer biomarkers including prostate-specific antigen (PSA), interleukin-6 (IL-6), and prostate-specific membrane antigen (PSMA). The microfluidic BPE chip shows good reproducibility and high sensitivity. The limits of detection for PSA, IL-6, and PSMA are 0.093 ng/mL, 0.061 pg/mL, and 0.059 ng/mL, respectively. It also exhibits excellent performance in real sample analysis. The integrated ECL BPE array shows a good application prospect in clinical sensing of cancer biomarkers, as well as point-of-care testing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available