4.4 Article

Spleen Size and Thrombocytopenia After Transcatheter Aortic Valve Implantation

Journal

AMERICAN JOURNAL OF CARDIOLOGY
Volume 157, Issue -, Pages 85-92

Publisher

EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
DOI: 10.1016/j.amjcard.2021.07.021

Keywords

-

Ask authors/readers for more resources

The study found that spleen size is associated with acquired thrombocytopenia after TAVI and correlates with 1-year mortality.
The pathophysiology of thrombocytopenia after transcatheter aortic valve implantation (TAVI) thrombocytopenia is still poorly understood. We assessed the association of spleen size with acquired thrombocytopenia in patients undergoing TAVI. We included 732 patients who underwent TAVI with new generation transcatheter heart valves (THVs) at our center from February 2016 to July 2019. We measured splenic volume index in consecutive patients derived from multidetector row computed tomographic datasets. Patients were stratified according to post-TAVI thrombocytopenia, which was defined as a decline in platelet count (DPC) >= 50% at nadir, and evaluated regarding baseline characteristics and outcome parameters. After the procedure, platelet counts declined from 212.9 +/- 67.4 x 10(9)/L at baseline to 138.8 +/- 49.8 x 10(9)/L at nadir after a median of 2 days (interquartile range [IQR] 2 to 3). Of all patients, 10.1% showed a DPC >= 50%. Compared with patients with DPC <50%, patients with DPC >= 50% had significantly lower splenic volume index (95.5 ml/m(2) [IQR 78.0 to 123.7] vs 85.8 ml/m(2) [IQR 71.4 to 102.6], p = 0.008). A multivariable analysis revealed that the splenic volume index was negatively associated with a DPC >= 50% (OR 0.89, 95% CI 0.82 to 0.97, p = 0.005), independent of the type of THV (balloon-expandable THV: OR 2.06, 95% CI 1.13 to 3.76, p = 0.02), major bleeding (OR 13.40, 95% CI 3.58 to 50.40, p <0.001), blood transfusion (OR 3.63, 95% CI 1.54 to 8.56, p = 0.003), or postprocedural paravalvular leakage >= moderate (OR 5.48, 95% CI 1.23 to 24.40, p = 0.03). Furthermore, DPC >= 50% was independently associated with 1-year mortality (HR 3.36, 95% CI 1.66 to 6.81, p <0.001). In conclusion, acquired thrombocytopenia remains prevalent in modern TAVI patients. Spleen size appears to be associated with the occurrence of thrombocytopenia after TAVI, which is independently correlated with 1-year mortality. (C) 2021 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available