4.7 Article

Association between ultrasound quality and test performance for HCC surveillance in patients with cirrhosis: a retrospective cohort study

Journal

ALIMENTARY PHARMACOLOGY & THERAPEUTICS
Volume 55, Issue 6, Pages 683-690

Publisher

WILEY
DOI: 10.1111/apt.16779

Keywords

-

Funding

  1. United States National Institute of Health [U01 CA230694, R01 CA222900, R01 CA212008]

Ask authors/readers for more resources

This study found that impaired ultrasound visualization is associated with worse surveillance test performance in patients with cirrhosis. Severe visual limitations were linked to lower sensitivity, while moderate limitations were associated with an increased risk of false-positive results. Alternative blood-based biomarkers and imaging strategies are needed for patients at risk of ultrasound-based surveillance failure.
Background Ultrasound visualisation is limited in approximately 20% of patients with cirrhosis undergoing hepatocellular carcinoma (HCC) surveillance; however, it is unknown if impaired visualisation directly impacts test performance. We aimed to evaluate the association between ultrasound visualisation and surveillance test performance. Methods We performed a retrospective cohort study among patients with cirrhosis, with or without HCC, who underwent ultrasound-based surveillance at two large health systems between July 2016 and July 2019. Ultrasound visualisation assessment was recorded by interpreting radiologists using the ultrasound LI-RADS Visualisation score. We performed logistic regression analyses to evaluate the association between ultrasound visualisation and diagnostic test performance. We assessed sensitivity for HCC detection among ultrasounds performed in the year prior to HCC diagnoses and specificity using ultrasounds in those without HCC. Results Among 186 patients with HCC, severely limited visualisation (Vis Score C) on ultrasound prior to HCC diagnosis was associated with increased odds of false-negative results, that is lower sensitivity (OR 7.94, 95% CI 1.23-51.16) in multivariable analysis. Ultrasound sensitivity with visualisation scores A or B exceeded 75%, compared to only 27.3% with visualisation score C. Among 2052 cirrhosis patients without HCC, moderate visualisation limitations (Vis score B) were associated with increased odds of false-positive results (OR 1.60, 1.13-2.27), although specificity exceeded 95% across all visualisation scores. Conclusions Impaired ultrasound visualisation is associated with worse surveillance test performance. Alternative blood-based biomarkers and imaging strategies are needed for patients at risk for ultrasound-based surveillance failure.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available