3.8 Article

Using a simplified ATP algorithm to improve data reliability and improve cleanliness standards for surface and medical device hygiene

Journal

INFECTION DISEASE & HEALTH
Volume 27, Issue 1, Pages 3-9

Publisher

ELSEVIER INC
DOI: 10.1016/j.idh.2021.07.001

Keywords

Cleanliness; ATP testing; Algorithm; Surface hygiene

Funding

  1. Whiteley Corporation

Ask authors/readers for more resources

The algorithm and duplicate sampling approach have improved the variability in cleanliness measurements of various surfaces. The cleaning intervention step provides a nuanced understanding of surface cleanliness.
Background: An algorithm has been improved to mitigate variability in cleanliness measurements of various surfaces using rapid Adenosine Triphosphate (ATP) testing. A cleaning intervention step (CIS) verifies the cleanability of those surfaces. Methods: ATP testing was performed on surfaces which were pre-approved as clean and ready for re-use. Adjacent (duplicate) ATP sampling was undertaken on 421 environmental surfaces, medical devices and other implements. The CIS was conducted on 270 surfaces using an aseptic technique and disposable cleaning wipes. Results: The two initial ATP results were plotted against each other with a 100 RLU threshold grading the results as clean (2x < 100RLU), dirty (2x > 100RLU) or equivocal (1x < 100RLU and 1x > 100RLU). Of the surfaces sampled, 68.5 % were clean (288/421), 13.5 % were dirty (57/ 421) and 18 % were equivocal (76/421). The duplicate testing demonstrated a false negative rate of 10 % (44/421) where the first swab was <100 RLU and the second swab >100 RLU. For the equivocal group, the gap between the two swabs was >100 RLU for 7.5 % of surfaces (33/421). The CIS was conducted on 270 of the surfaces tested and showed that cleaning could be improved (P=<0.001) on 88.5 % of surfaces (239/270). Conclusion: The simplified ATP testing algorithm provides real-time discrimination between surface cleanliness levels and improved certainty over surface hygiene. The duplicate swab sampling approach mitigates uncontrolled variability in the results and the CIS provides a nuanced understanding of the measurable cleanliness of any surface. (C) 2021 The Author(s). Published by Elsevier B.V. on behalf of Australasian College for Infection Prevention and Control.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available