3.9 Article

Half-life of 67Cu

Journal

JOURNAL OF PHYSICS COMMUNICATIONS
Volume 5, Issue 8, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/2399-6528/ac1ad8

Keywords

half-life; copper-67; nuclear data; Cu-67

Funding

  1. US Department of Energy Isotope Program

Ask authors/readers for more resources

The half-life of Cu-67 was determined with high precision through gamma-ray spectrometry measurements and least-squares regression analysis, resulting in a value of 61.761 +/- 0.004 hours. This represents a significant improvement over current data and marks a new level of accuracy in the field.
The half-life of Cu-67 was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E (gamma) : 184.6 keV; branching ratio: 48.7%) produced following beta- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of Cu-67. The result was 61.761 +/- 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available