4.3 Article

BAY 81-8973, a full-length recombinant factor VIII: results from an International comparative laboratory field study

Journal

HAEMOPHILIA
Volume 22, Issue 3, Pages E192-E199

Publisher

WILEY-BLACKWELL
DOI: 10.1111/hae.12925

Keywords

chromogenic assay; factor VIII; field study; one-stage assay; postinfusion monitoring; recombinant factor VIII

Categories

Ask authors/readers for more resources

Introduction: BAY 81-8973 is a full-length, unmodified, recombinant human factor VIII (FVIII) with the same primary amino acid sequence as sucrose-formulated recombinant FVIII but produced with certain more advanced manufacturing technologies. Aim: This global laboratory study evaluated variability in measurement of BAY 818973 using one-stage and chromogenic assays compared with antihaemophilic factor (recombinant) plasma/albumin-free method (rAHF-PFM; Advate (R)) under assay conditions routinely used in clinical laboratories. Methods: BAY 81-8973 or rAHF-PFM was spiked into FVIII-deficient plasma at 0.043 (low), 0.375 (medium) and 0.865 (normal) IU mL(-1). Participating laboratories analysed blinded samples and normal plasma in triplicate using their routine assay, reagents and standards. Results were analysed for intra-and interlaboratory variability. Results: Forty-one laboratories in 11 countries participated in the study. One-stage assay and chromogenic assays were used by 40 and 10 laboratories, respectively; 9 laboratories used both assays. Intralaboratory variability was <11% for both assays and both products at all concentrations. Interlaboratory variability was highest at the low concentration in the chromogenic and one-stage assay for BAY 81-8973 (60.0% and 33.7%, respectively) and rAHF-PFM (51.0% and 30.8%) and was lowest at the normal concentration (BAY 81-8973, 5.4% and 14.0%; rAHF-PFM, 5.8% and 12.4%), which was similar to the plasma control (6.6% and 10.3%). The chromogenic: one-stage assay ratio ranged from 0.95 (low concentration) to 1.10 (normal concentration) for BAY 81-8973 and 0.96-1.18 for rAHF-PFM. Conclusions: BAY 81-8973 can be accurately measured in plasma using the one-stage and chromogenic assays routinely used in clinical laboratories without a product-specific standard.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available