4.7 Article

Numerical investigation of the heat and mass transfer performance of a two-phase closed thermosiphon based on a modified CFD model

Journal

CASE STUDIES IN THERMAL ENGINEERING
Volume 26, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.csite.2021.101155

Keywords

Volume of model; Adjust & control strategy; Heat transfer mechanism; Two-phase flow; Two-phase closed thermosiphon

Categories

Funding

  1. National Natural Science Foundation of China [51806100]
  2. Natural Science Foundation of Jiangsu Province [BK20180706]
  3. Postgraduate Research & Practice Innovation Program of Jiangsu Province [KYCX20_1000]
  4. Startup Foundation for Introduced Talents of Nanjing Tech University
  5. High-Performance Computing Center of Nanjing Tech University

Ask authors/readers for more resources

An improved CFD model was developed and verified by experiments to study the heat and mass transfer performance of a two-phase closed thermosiphon. The results showed that the model could accurately predict the heat and mass transfer behaviors of TPCT.
A modified CFD model was developed to investigate the heat and mass transfer performance of a two-phase closed thermosiphon (TPCT). In this model, the phase-change temperature of the working fluid was considered to be dependent on the local pressure. Meanwhile, an auto-adjust and control strategy was established for the condensation mass transfer time relaxation parameter, which could balance the phase-change pressure to the working pressure. The modified phase-change model was verified by experiments and then used to investigate the heat and mass transfer behaviors of the TPCT under different heat flux of 12.31-15.95 kW/m(2). The results indicated that the maximum relative errors of wall temperature and working pressure of the TPCT were 0.25-0.48% and 0.14-0.46%, respectively. The wall temperature gradually decreases from the bottom of evaporator to adiabatic section, and then increases from the bottom to the top of the condenser due to the temperature difference between the inlet and outlet of the cooling water. Also, as the heat flux increase, the overall thermal resistance reduces from 0.060 to 0.055 K/W. These results indicate that the proposed model can be used to predict the heat and mass transfer of the TPCT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available