4.3 Article

Terminal augmented ureteroplasty with bladder onlay flap technique for recurrent distal ureteral stricture after ureteroneocystostomy: an initial case series

Journal

TRANSLATIONAL ANDROLOGY AND UROLOGY
Volume 10, Issue 8, Pages 3332-3339

Publisher

AME PUBL CO
DOI: 10.21037/tau-21-252

Keywords

Bladder onlay flap; recurrent distal ureteral stenosis; ureteroneocystostomy

Ask authors/readers for more resources

The study retrospectively analyzed the treatment effect of ureteroplasty with a bladder onlay flap in 6 patients, showing a high success rate with significant symptom improvement postoperatively. No serious complications occurred during the operation, indicating a certain efficacy for patients with previous unsuccessful surgeries.
Background: Bladder flap has been shown to be a feasible treatment for distal ureteral stenosis; this technique has been improved such that it can be used to address complex urinary tract obstructions. The purpose of the present study was to describe a surgical technique of ureteroplasty with a bladder onlay flap, which consists of a nontransecting and terminal augmented anastomosis, for repairing recurrent distal strictures of the ureter. Methods: We retrospectively reviewed 6 patients who underwent this procedure between May 2018 and November 2019. These patients were diagnosed with distal ureteral stenosis and had previously undergone ureteroneocystostomy (one with a Boari flap) but suffered recurrence of flank pain. Patient characteristics, perioperative data and follow-up outcomes were gathered. The success of the operation was judged by symptomatic relief (subjective success) and improved radiographic imaging and renal function (objective success). Results: Preoperative computed tomography urography (CTU) showed hydronephrosis in all patients: severe hydronephrosis was observed in 83.3% of patients (5/6), and moderate hydronephrosis was observed in 16.7% (1/6). The mean stricture length was 2 cm. The mean operating time, estimated blood loss and postoperative hospital stays of the six patients were 193.3 min (160-270 min), 41.5 mL (10-58 mL) and 8.2 days (6-11 days), respectively. No serious complications (Clavien-Dindo grade >= 3) occurred during or after the operations. The mean follow-up time was 24.5 months (range, 14 to 29). The objective success rate was 83.3% (5/6), and the subjective success rate was 100%. Conclusions: Our technique of ureteroplasty with a bladder onlay flap by nontransecting and terminal augmented anastomosis is feasible and improves the recovery rate after the repair of recurrent distal ureteral stenosis. Patients who have had previous unsuccessful surgeries might benefit from this approach.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available