4.7 Article

Detection of Peanut Allergen by Real-Time PCR: Looking for a Suitable Detection Marker as Affected by Processing

Journal

FOODS
Volume 10, Issue 6, Pages -

Publisher

MDPI
DOI: 10.3390/foods10061421

Keywords

real-time PCR; peanut; food allergen; chloroplast marker; DNA isolation

Funding

  1. Spanish Ministerio de Ciencia e Innovacion [AGL2017-83082-R]

Ask authors/readers for more resources

This study used chloroplast markers and real-time PCR to enhance the sensitivity of peanut detection, applying different DNA extraction protocols, selecting appropriate primers and probes for detection, and ultimately determining that the mat k chloroplast marker was the most sensitive. The method is also capable of accurately detecting peanuts in processed foods, with a wide range of potential applications.
Peanut (Arachis hypogaea) contains allergenic proteins, which make it harmful to the sensitised population. The presence of peanut in foods must be indicated on label, to prevent accidental consumption by allergic population. In this work, we use chloroplast markers for specific detection of peanut by real-time PCR (Polymerase Chain Reaction), in order to increase the assay sensitivity. Binary mixtures of raw and processed peanut flour in wheat were performed at concentrations ranging from 100,000 to 0.1 mg/kg. DNA isolation from peanut, mixtures, and other legumes was carried out following three protocols for obtaining genomic and chloroplast-enrich DNA. Quantity and quality of DNA were evaluated, obtaining better results for protocol 2. Specificity and sensitivity of the method has been assayed with specific primers for three chloroplast markers (mat k, rpl16, and trnH-psbA) and Ara h 6 peanut allergen-coding region was selected as nuclear low-copy target and TaqMan probes. Efficiency and linear correlation of calibration curves were within the adequate ranges. Mat k chloroplast marker yielded the most sensitive and efficient detection for peanut. Moreover, detection of mat K in binary mixtures of processed samples was possible for up to 10 mg/kg even after boiling, and autoclave 121 degrees C 15 min, with acceptable efficiency and linear correlation. Applicability of the method has been assayed in several commercial food products.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available