4.7 Article

The Influence of Kinematic Constraints on Model Performance During Inverse Kinematics Analysis of the Thoracolumbar Spine

Journal

Publisher

FRONTIERS MEDIA SA
DOI: 10.3389/fbioe.2021.688041

Keywords

spine motion; degrees of freedom; dynamic movement; smoothness of motion; optoelectronic motion capture

Funding

  1. National Institute on Aging of the National Institutes of Health [R00AG042458]
  2. National Institute of Arthritis and Musculoskeletal and Skin Diseases of the National Institutes of Health [R01AR073019]
  3. Department of Orthopaedic Surgery at Beth Israel Deaconess Medical Center
  4. Harvard Catalyst, The Harvard Clinical and Translational Science Center (National Center for Advancing Translational Sciences, National Institutes of Health Award) [UL1 TR001102]
  5. Harvard University
  6. NRSA [T32AR55885]
  7. Office of the Assistant Secretary of Defense for Health Affairs through the Peer Reviewed Medical Research Program [W81XWH-20-1-0608]
  8. National Institute on Aging [F32AG071308]

Ask authors/readers for more resources

The study evaluated the performance of different kinematic constraints for inverse kinematics analysis in spine motion. Results showed that adding more DOF to kinematic constraints did not notably improve performance, with 4-6DOF constraints producing similar levels of smoothness and physiologically reasonable joint ROMs. A kinematic constraint with 5DOF was found to produce smooth spine motions with relatively low marker error.
Motion analysis is increasingly applied to spine musculoskeletal models using kinematic constraints to estimate individual intervertebral joint movements, which cannot be directly measured from the skin surface markers. Traditionally, kinematic constraints have allowed a single spinal degree of freedom (DOF) in each direction, and there has been little examination of how different kinematic constraints affect evaluations of spine motion. Thus, the objective of this study was to evaluate the performance of different kinematic constraints for inverse kinematics analysis. We collected motion analysis marker data in seven healthy participants (4F, 3M, aged 27-67) during flexion-extension, lateral bending, and axial rotation tasks. Inverse kinematics analyses were performed on subject-specific models with 17 thoracolumbar joints allowing 51 rotational DOF (51DOF) and corresponding models including seven sets of kinematic constraints that limited spine motion from 3 to 9DOF. Outcomes included: (1) root mean square (RMS) error of spine markers (measured vs. model); (2) lag-one autocorrelation coefficients to assess smoothness of angular motions; (3) maximum range of motion (ROM) of intervertebral joints in three directions of motion (FE, LB, AR) to assess whether they are physiologically reasonable; and (4) segmental spine angles in static ROM trials. We found that RMS error of spine markers was higher with constraints than without (p < 0.0001) but did not notably improve kinematic constraints above 6DOF. Compared to segmental angles calculated directly from spine markers, models with kinematic constraints had moderate to good intraclass correlation coefficients (ICCs) for flexion-extension and lateral bending, though weak to moderate ICCs for axial rotation. Adding more DOF to kinematic constraints did not improve performance in matching segmental angles. Kinematic constraints with 4-6DOF produced similar levels of smoothness across all tasks and generally improved smoothness compared to 9DOF or unconstrained (51DOF) models. Our results also revealed that the maximum joint ROMs predicted using 4-6DOF constraints were largely within physiologically acceptable ranges throughout the spine and in all directions of motions. We conclude that a kinematic constraint with 5DOF can produce smooth spine motions with physiologically reasonable joint ROMs and relatively low marker error.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available