4.7 Article

Insights into corrosion behaviour of uncoated Mg alloys for biomedical applications in different aqueous media

Journal

JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T
Volume 13, Issue -, Pages 1908-1922

Publisher

ELSEVIER
DOI: 10.1016/j.jmrt.2021.05.090

Keywords

Magnesium alloys; Biomedical applications; In vitro cytotoxicity; Corrosion protection

Funding

  1. Portugal 2020 through European Regional Development Fund (ERDF) by Portuguese Foundation for Science and Technology/MCTES [MAGICOAT POCI-01-0145-FEDER-016597/PTDC/CTM-BIO/2170/2014, UIDB/50011/2020, UIDP/50011/2020]
  2. Portuguese Foundation for Science and Technology/MCTES [UIDB/04750/2020]

Ask authors/readers for more resources

The study investigated the cytotoxicity and corrosion behavior of Mg1Ca and Mg10Gd alloys in different electrolytes, revealing that Mg1Ca alloy has a lower degradation rate and lower cytotoxicity, showing promise for biomedical implants.
MgCa and MgGd series of alloys are often reported as promising candidates for biomedical applications. In the present study, cytotoxicity and corrosion behavior of Mg1Ca and Mg10Gd alloys in different electrolytes (NaCl, PBS, MEM) have been investigated in order to make a direct comparison and understand the mechanisms behind their performance. Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) were employed to analyze corrosion processes depending on media composition, whereas X-Ray diffraction (XRD) and scanning electron microscopy (SEM) were used to evaluate crystalline structure, phase composition and surface morphology of the corroded substrates after immersion in the different electrolytes. Moreover, cytotoxicity of the Mg alloys was assessed using the WST-1 reduction and lactate dehydrogenase (LDH) release assays in L929 mouse fibroblasts. The electrochemical results showed that Mg1Ca has a lower degradation rate when compared to Mg10Gd, due to the lower microgalvanic effects and the presence of Ca as an alloying element. Furthermore, the corrosion activity is reduced in MEM, for both alloys, when compared to NaCl and PBS. The cytotoxicity assays revealed that Mg10Gd was cytotoxic in all the conditions tested, while the toxicity of Mg1Ca was low. Overall, these findings show that Mg1Ca alloy presents a higher corrosion resistance and biocompatibility and is a promising material to be used in biomedical implants.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available