4.6 Article

Intra- and Inter-Rater Reliability of a Well-Used and a Less-Used IsoMed 2000 Dynamometer for Knee Flexion and Extension Peak Torque Measurements in a Concentric Test in Athletes

Journal

APPLIED SCIENCES-BASEL
Volume 11, Issue 11, Pages -

Publisher

MDPI
DOI: 10.3390/app11114951

Keywords

muscle strength; muscle strength dynamometer; quadriceps muscle; hamstring muscles

Ask authors/readers for more resources

This study evaluated the intra- and inter-rater reliability of IsoMed-2000 dynamometers for knee flexion and extension peak torque measurements in athletes. The results showed moderate to excellent reliability, with the highest Smallest Detectable Change and Standard Error Measurement values of 0.76 N/kg and 0.28 N/kg respectively.
This study aimed to evaluate the intra- and inter-rater reliability of a well-used and a less-used IsoMed-2000 dynamometer for knee flexion and extension peak torque (PT) measurements in a concentric test in athletes. Two IsoMed-2000 isokinetic dynamometers were used, an old one that was well-used and a new one that was less-used. Thirty-seven weight-lifting athletes (12 female, 25 male) were included in this study. Both legs of each athlete were tested twice on each isokinetic dynamometer at 60 degrees/s and 180 degrees/s. The Intraclass Correlation Coefficients (ICC), Standard Error Measurement (SEM), Smallest Detectable Change (SDC), SDC% and 95% limits of agreement were calculated to evaluate the intra- and inter-rater reliability of a well-used and a less-used IsoMed 2000 dynamometer for knee flexion and extension peak torque in athletes. Intra-rater reliability was moderate to excellent (ICCs: 0.516-0.928) for knee muscle strength parameters, and the highest SDC and SEM values were 0.76 N/kg and 0.28 N/kg, respectively. Inter-rater reliability was moderate to excellent (ICCs: 0.519-915) for knee muscle strength parameters, and the highest SDC and SEM values were 0.81 N/kg and 0.29 N/kg, respectively. At least 89.2% of the obtained values of parameters fell within the 95% limits of agreement. Our findings demonstrate the intra and inter-rater reliability of a Well-Used and a Less-Used IsoMed 2000 Dynamometer for Knee Flexion and Extension Peak Torque in Athletes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available