4.7 Article

Biomaterial Wettability Affects Fibrin Clot Structure and Fibrinolysis

Journal

ADVANCED HEALTHCARE MATERIALS
Volume 10, Issue 20, Pages -

Publisher

WILEY
DOI: 10.1002/adhm.202100988

Keywords

biomaterials; fibrin clot structure; fibrinolysis; microfluidics; polystyrene; wettability

Funding

  1. Australian Research Council DECRA [DE160101308]
  2. Clive and Vera Ramaciotti Foundations Health Investment Grant
  3. National Heart Foundation of Australia [103004]
  4. University of Sydney, Heart Research Institute
  5. University of Sydney Nano Institute
  6. Australian Government Research Training Program (RTP) Scholarship
  7. University of Sydney RTP Supplementary Scholarship
  8. USYD CPC EMCR Seed Fund
  9. Heart Research Institute
  10. School of Biomedical Engineering, University of Sydney
  11. Australian Research Council [DE160101308] Funding Source: Australian Research Council

Ask authors/readers for more resources

The wettability of materials influences fibrin fiber formation at material interfaces, resulting in differences in bulk fibrin clot density and susceptibility to fibrinolysis. These findings have significant implications for the thrombus formation in stagnant or low-flow regions of medical devices and the design of nonthrombogenic materials.
Thrombosis on blood-contacting medical devices can cause patient fatalities through device failure and unstable thrombi causing embolism. The effect of material wettability on fibrin network formation, structure, and stability is poorly understood. Under static conditions, fibrin fiber network volume and density increase in clots formed on hydrophilic compared to hydrophobic polystyrene surfaces. This correlates with reduced plasma clotting time and increased factor XIIa (FXIIa) activity. These structural differences are consistent up to 50 mu m away from the material surface and are FXIIa dependent. Fibrin forms fibers immediately at the material interface on hydrophilic surfaces but are incompletely formed in the first 5 mu m above hydrophobic surfaces. Additionally, fibrin clots on hydrophobic surfaces have increased susceptibility to fibrinolysis compared to clots formed on hydrophilic surfaces. Under low-flow conditions, clots are still denser on hydrophilic surfaces, but only 5 mu m above the surface, showing the combined effect of the surface wettability and coagulation factor dilution with low flow. Overall, wettability affects fibrin fiber formation at material interfaces, which leads to differences in bulk fibrin clot density and susceptibility to fibrinolysis. These findings have implications for thrombus formed in stagnant or low-flow regions of medical devices and the design of nonthrombogenic materials.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available