The study found that using an instrument tracking system in minimally invasive lumbar fusion surgery significantly reduces radiation exposure and operative time, leading to higher efficiency and safety compared to conventional fluoroscopy.
BACKGROUND: Minimally invasive surgical techniques have resulted in improved patient outcomes. One drawback has been the increased reliance on fluoroscopy and subsequent exposure to ionizing radiation. We have previously shown the efficacy of a novel instrument tracking system in cadaveric and preliminary clinical studies for commonplace orthopedic and spine procedures. In the present study, we examined the radiation and operative time using a novel instrument tracking system compared with standard C-arm fluoroscopy for patients undergoing minimally invasive lumbar fusion. METHODS: The radiation emitted, number of radiographs taken, and time required to complete 2 tasks were recorded between the instrument tracking systems and conventional C-arm fluoroscopy. The studied tasks included placement of the initial dilator through Kambin's triangle during percutaneous lumbar interbody fusion and placement of pedicle screws during both percutaneous lumbar interbody fusion and minimally invasive transforaminal lumbar interbody fusion with or without instrument tracking. RESULTS: A total of 23 patients were included in the analysis encompassing 31 total levels. For the task of placing the initial dilator into Kambin's triangle, an average of 4.21 minutes (2.4 vs. 6.6 minutes; P = 0.002), 15 fluoroscopic images (5.4 vs. 20.5; P = .002), and 8.14 mGy (3.3 vs. 11.4; P = 0.011) were saved by instrument tracking. For pedicle screw insertion, an average of 5.69 minutes (3.97 vs. 9.67; P < 0.001), 14 radiographs (6.53 vs. 20.62; P < 0.001), and 7.89 mGy (2.98 vs. 10.87 mGy; P < 0.001) were saved per screw insertion. CONCLUSIONS: Instrument tracking, when used for minimally invasive lumbar fusion, leads to significant reductions in radiation and operative time compared with conventional fluoroscopy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available