4.6 Article

Effect of Temperature on Electrochemically Assisted Deposition and Bioactivity of CaP Coatings on CpTi Grade 4

Journal

MATERIALS
Volume 14, Issue 17, Pages -

Publisher

MDPI
DOI: 10.3390/ma14175081

Keywords

amorphous calcium phosphate; bioactivity; electrochemically assisted deposition; titanium

Funding

  1. Research Excellence Initiative of the University of Silesia in Katowice

Ask authors/readers for more resources

The method of producing calcium phosphate coatings has a significant impact on the properties of the final product, with electrochemically assisted deposition (ECAD) being particularly important for its high repeatability at room temperature and neutral pH. Studies have shown that under optimized conditions, amorphous calcium phosphate coatings with good biocompatibility can be obtained for use in simulated body fluids.
Calcium phosphate (CaP) coatings are able to improve the osseointegration process due to their chemical composition similar to that of bone tissues. Among the methods of producing CaP coatings, the electrochemically assisted deposition (ECAD) is particularly important due to high repeatability and the possibility of deposition at room temperature and neutral pH, which allows for the co-deposition of inorganic and organic components. In this work, the ECAD of CaP coatings from an acetate bath with a Ca:P ratio of 1.67, was developed. The effect of the ECAD conditions on CaP coatings deposited on commercially pure titanium grade 4 (CpTi G4) subjected to sandblasting and autoclaving was presented. The physicochemical characteristics of the ECAD-derived coatings was carried out using SEM, EDS, FTIR, 2D roughness profiles, and amplitude sensitive eddy current method. It was showed that amorphous calcium phosphate (ACP) coatings can be obtained at a potential -1.5 to -10 V for 10 to 60 min at 20 to 70 degrees C. The thickness and surface roughness of the ACP coatings were an increasing function of potential, time, and temperature. The obtained ACP coatings are a precursor in the process of apatite formation in a simulated body fluid. The optimal ACP coating for use in dentistry was deposited at a potential of -3 V for 30 min at 20 degrees C.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available