4.1 Article

A Conformable Two-Dimensional Resistance Temperature Detector for Measuring Average Skin Temperature

Journal

Publisher

ASME
DOI: 10.1115/1.4051442

Keywords

Resistance thermometers; Sensors; Skin; Temperature; Calibration; Thermocouples

Funding

  1. National Institutes of Health [2R42GM119871]

Ask authors/readers for more resources

Research on thermoregulation and medical procedures involving skin temperature manipulation is crucial. Skin temperature monitoring is essential to prevent thermal injury. Existing methods for skin temperature monitoring have limitations, but a new two-dimensional resistance temperature detector (2D RTD) has been shown to be superior in measuring average skin temperature in nonuniform temperature fields.
Thermoregulation research and various medical procedures are accomplished by manipulating skin temperature in a nonuniform pattern. Skin temperature monitoring is essential to assess conformance to protocol specifications and to prevent thermal injury. Existing solutions for skin temperature monitoring include single point sensors, such as thermocouples, and two-dimensional methods of sensing surface temperature, such as infrared thermography, and wearable technology. Single point sensors cannot detect the average temperature and consequently their measurements cannot be representative of average surface temperature in a nonuniform temperature field. Infrared thermography requires optical access, and existing ambulatory sensors may require complex manufacturing processes and impede the heat exchange with a source by including a structural substrate layer. Our solution is a two-dimensional resistance temperature detector (two-dimensional (2D) RTD) created by knitting copper magnet wire into custom shapes. The 2D RTDs were calibrated, compared to one-dimensional sensors and wearable sensors, and analyzed for hysteresis, repeatability, and surface area conformation. Resistance and temperature were correlated with an R-2 of 0.99. The 2D RTD proved to be a superior device for measuring average skin temperature over a defined area exposed to a nonuniform temperature boundary in the absence of optical access such as when a full body thermal control garment is worn.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available