4.7 Article

Total attenuation compensation for backscatter coefficient estimation using full angular spatial compounding

Journal

ULTRASONICS
Volume 114, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.ultras.2021.106376

Keywords

Quantitative ultrasound; Spatial compounding; Tomography; Attenuation coefficient slope; Backscatter coefficient; Ultrasound tissue characterization

Funding

  1. National Council of Science, Technology and Technological Innovation (CONCYTEC, Peru) through the National Fund for Scientific, Technological Development and Technological Innovation (FONDECYT, Peru) [132-2016]
  2. Peruvian government (CONCYTEC) [08-2013FONDECYT]
  3. Pontificia Universidad Catolica del Peru [DGI-2019-0693]
  4. NIH [R01CA251939, R21EB024133]

Ask authors/readers for more resources

In this study, a method using attenuation maps constructed using full angular spatial compounding (FASC) for attenuation compensation when imaging integrated backscatter coefficients (BSCs) was proposed. Experimental validation showed that reliable estimation of BSCs can be achieved when a self-consistent attenuation compensation stemming from prior estimation of an accurate attenuation coefficient slope (ACS) map is used.
The backscatter coefficient (BSC) quantifies the frequency-dependent reflectivity of tissues. Accurate estimation of the BSC is only possible with the knowledge of the attenuation coefficient slope (ACS) of the tissues under examination. In this study, the use of attenuation maps constructed using full angular spatial compounding (FASC) is proposed for attenuation compensation when imaging integrated BSCs. Experimental validation of the proposed approach was obtained using two cylindrical physical phantoms with off-centered inclusions having different ACS and BSC values than the background, and in a phantom containing an ex vivo chicken breast sample embedded in an agar matrix. With the phantom data, three different ACS maps were employed for attenuation compensation: (1) a ground truth ACS map constructed using insertion loss techniques, (2) the estimated ACS map using FASC attenuation imaging, and (3) a uniform ACS map with a value of 0.5 dBcm(-1)MHz(-1), which is commonly used to represent attenuation in soft tissues. Comparable results were obtained when using the ground truth and FASC-estimated ACS maps in term of inclusion detectability and estimation accuracy, with averaged fractional error below 2.8 dB in both phantoms. Conversely, the use of the homogeneous ACS map resulted in higher levels of fractional error (> 10 dB), which demonstrates the importance of an accurate attenuation compensation. The results with the ex vivo tissue sample were consistent with the observations using the physical phantoms, with the FASC-derived ACS map providing comparable BSC images to those formed using the ground truth ACS map and more accurate than those BSC images formed using a uniform ACS. These results suggest that BSCs can be reliably estimated using FASC when a self-consistent attenuation compensation stemming from prior estimation of an accurate ACS map is used.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available