4.5 Article

Mathematical model used for predicting arc-flash protective performance of fabrics based on physical parameters

Journal

TEXTILE RESEARCH JOURNAL
Volume 91, Issue 23-24, Pages 2962-2968

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/00405175211022633

Keywords

Thermal protective performance; arc protective fabric; arc thermal protective value test; multiple linear regression

Funding

  1. National Key Research and Development Program of China [2018YFC0810302]
  2. Postgraduate Research & Practice Innovation Program of Jiangsu Province [KYCX19-2063]

Ask authors/readers for more resources

This study systematically analyzed parameters that may affect the performance of arc-flash protective fabrics. Sixteen different fabrics were produced and investigated, revealing different effects on arc protective performance. A predicting mathematical model was developed based on the parameters that have the greatest influence, demonstrating the rationality of using multiple linear regression to accurately predict arc protective performance.
In this study, parameters that may affect the performance of arc-flash protective fabrics were systematically analyzed. Sixteen different commonly used fabrics with different configurations and grammage were produced and investigated, namely four raw materials with different configurations (93:0:5:2, 70:23:5:2, 46:47:5:2, and 23:70:5:2) and four with different grammage (180, 210, 240, and 270 g/m(2)). It was found that factors had different effects on the arc protective performance. Principal component analysis showed that the four plain weave fabrics of 180 g/m(2) behaved differently compared with other samples, which was ascribed to the related differences in weave structure. In addition, a predicting mathematical model was developed based on the parameters that have the greatest influence on arc protective performance. The prediction parameters were not added to the structure, but replaced with physical parameters such as air permeability and thermomechanical properties. The adjusted R-2 was 0.867, which demonstrated the rationality of using multiple linear regression to accurately predict arc protective performance. It was hypothesized that the construction of the mathematical model could contribute to the arc protective fabric evaluation and future researches in this field.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available