4.7 Article

Microfluidic colorimetric detection platform with sliding hybrid PMMA/paper microchip for human urine and blood sample analysis

Journal

TALANTA
Volume 231, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2021.122362

Keywords

Microfluidic; Colorimetric; Paper-chip; Total protein; Albumin; Creatine

Funding

  1. Ministry of Science and Technology of Taiwan [MOST 106-2314-B-006-085-MY3, MOST 106-2221-E-006-253-MY3, MOST 108-2622-E -006-026-CC, MOST 109-2221-E-006 -043 -MY3]

Ask authors/readers for more resources

A microfluidic colorimetric detection platform using a sliding hybrid PMMA/paper microchip and a smart analysis system is proposed for convenient, low-cost, and rapid analysis of human urine and whole blood samples. The platform has been shown to produce consistent results with a conventional hospital analysis system for total protein, albumin, and creatine concentrations.
A microfluidic colorimetric detection (MCD) platform consisting of a sliding hybrid PMMA/paper microchip and a smart analysis system is proposed for the convenient, low-cost and rapid analysis of human urine and whole blood samples. The sliding PMMA/paper microchip comprises a PMMA microfluidic chip for sample injection and transportation, a paper strip for sample filtration (urine) or separation (blood), and a sealed paper-chip detection zone for sample reaction and detection. In the proposed device, the paper-chip is coated with bicinchoninic acid (BCA) and biuret reagent and is then assembled into the PMMA microchip and packaged in aluminum housing. In the detection process, the PMMA/paper microchip is slid partially out of the housing, and 2 mu L of sample (urine or whole blood) is dripped onto the sample injection zone. The chip is then slid back into the housing and the sample is filtered/separated by the paper strip and transferred under the effects of capillary action to the sealed paper-chip detection zone. The housing is inserted into the color analysis system and heated at 45 degrees C for 5 min to produce a purple-colored reaction complex. The complex is imaged using a CCD camera and the RGB color intensity of the image is then analyzed using a smartphone to determine the total protein (TP) concentration of the sample. The effectiveness of the proposed method is demonstrated using TP control samples with known concentrations in the range of 0.03-5.0 g/dL. The detection results obtained for 50 human urine samples obtained from random volunteers are shown to be consistent with those obtained from a conventional hospital analysis system (R-2 = 0.992). Moreover, the detection results obtained for the albumin (ALB) and creatine (CRE) concentrations of 50 whole blood samples are also shown to be in good agreement with the results obtained from the hospital analysis system (R-2 = 0.982 and 0.988, respectively).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available