4.7 Article

Spreading resistance modeling for rapid extraction of contact resistivity with a four-point probe

Journal

SOLAR ENERGY MATERIALS AND SOLAR CELLS
Volume 230, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.solmat.2021.111272

Keywords

Contact resistivity; Four-point probe; Characterization

Funding

  1. TUBITAK [118M981]

Ask authors/readers for more resources

This study presents a new method for extracting contact resistivity using the four-point probe method, utilizing a spreading resistance model to significantly reduce calculation time. The resolution and reliability of the extracted pc critically depend on the geometrical and electrical parameters of the system. An alternative measurement procedure based on only one substrate is also proposed, and a free software for executing the calculations discussed is provided.
Extraction of contact resistivity (pc) with the four-point probe (4PP) method requires considerably fewer fabrication and measurement steps compared to conventional alternatives (e.g. the transfer length method, TLM). Yet, the method is rarely used, mainly due to the requirement of 3D simulations used in the data fitting procedure. Moreover, a work analyzing the details of the method, which can provide a quantitative guideline to the users, is lacking in the literature. In this work, we show that the 3D simulations can be replaced with a spreading resistance model (SRM) implemented in a numerical calculation platform (e.g. MATLAB). Using the SRM, we achieve drastically short calculation durations (<1 s) compared to durations of 3D simulations based on the finite element method. We show that the resolution and reliability of the extracted pc depends critically on geometrical and electrical parameters of the system, such as the probe tip spacing and sheet resistances of the layers. We also present an alternative measurement procedure that is fully based on 4PP measurements of only one substrate, which eliminates the need for an eddy-current measurement or an additional set of dedicated samples. We demonstrate the viability of the 4PP method in experiments by comparing the results with those obtained by the TLM, for pc between 5 x 10-3 to 1 x 100 S2 cm2. Lastly, we provide a free software that can execute the calculations discussed herein.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available