4.7 Article

Effects of air pollution control devices on volatile organic compounds reduction in coal-fired power plants

Journal

SCIENCE OF THE TOTAL ENVIRONMENT
Volume 782, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.scitotenv.2021.146828

Keywords

Coal-fired power plant; VOCs; Air pollution control devices; Ozone formation potential; Emission factor

Funding

  1. National Key Research and Development Program of China [2018YFB0605200]
  2. National Natural Science Foundation of China [22076207]

Ask authors/readers for more resources

This study investigated VOC concentrations in flue gas samples from coal-fired power plants and industrial boilers. It found that SCR systems and ESP can synergistically remove VOCs, while WFGD affects different VOCs in varying ways. Wet electrostatic precipitators (WESP) were found to increase VOC emissions.
Air pollution control devices (APCDs) have been fitted to many coal-fired power plants to decrease the impacts of pollutants generated during coal combustion. APCDs remove conventional pollutants but also decrease volatile organic compound (VOC) emissions. In this study, flue gas samples were collected from different points in seven typical coal-fired power and two industrial boilers, and the VOC concentrations in the flue gas samples were determined by gas chromatography-mass spectrometry (GC-MS). Selective catalytic reduction (SCR) systems and electrostatic precipitators (ESP) can synergistically remove VOCs, the mean removal rate of VOCs by ESP was 42% +/- 9%. This was caused by the catalyst in SCR systems and the condensation process in the ESP. Wet flue gas desulfurization (WFGD) affected different VOCs in different ways, increasing the halogenated hydrocarbons and aromatic hydrocarbons concentrations but decreasing the oxygenated VOCs concentrations by 12%. Wet electrostatic precipitators (WESP) increased VOC emissions. By calculating Ozone formation potential (OFP), aromatic hydrocarbons are important contributors to ozone production. The emission factor of the power plant was 0.69 g/GJ, and the Chinese annual emission was about 1.2 x 10(4) t. VOCs emissions in different regions were affected by factors such as the economy and population. VOC emissions can be decreased by using the most appropriate unit load and improving the VOC removal efficiencies of the APCDs. (C) 2021 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available