4.6 Article

Sensitivity assessment of workflows detecting rare circulating cell-free DNA targets: A study design proposal

Journal

PLOS ONE
Volume 16, Issue 7, Pages -

Publisher

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0253401

Keywords

-

Ask authors/readers for more resources

Liquid biopsy has seen significant growth in recent decades, especially in the use of circulating cell-free DNA (ccfDNA) as an analyte in diagnostic assays. Establishing an unbiased experimental setup to test factors affecting assay sensitivity is crucial in diagnostic or research laboratories. Differences in performance between two widely used blood ccfDNA profile stabilization technologies were observed in a proof of principle study, highlighting the importance of verifying and validating a liquid biopsy workflow from blood collection to analytical result.
The field of liquid biopsy has seen extensive growth in recent decades, making it one of the most promising areas in molecular diagnostics. Circulating cell-free DNA (ccfDNA) especially is used as an analyte in a growing number of diagnostic assays. These assays require specified preanalytical workflows delivering ccfDNA in qualities and quantities that facilitate correct and reliable results. As each step and component used in the preanalytical process has the potential to influence the assay sensitivity and other performance characteristics, it is key to find an unbiased experimental setup to test these factors in diagnostic or research laboratories. We defined one such setup by using blood from healthy subjects and commercially available products for blood collection, spike-in material, ccfDNA isolation, and qPCR assays. As the primary read-out, we calculated the probit model-based LOD95 (limit of detection of the 95(th) percentile) from the qPCR assay results. In a proof of principle study we tested two different but widely used blood ccfDNA profile stabilization technologies in blood collection tubes, the Cell-Free DNA BCT and the PAXgene Blood ccfDNA Tube. We tested assays for three different EGFR gene mutations and one BRAF gene mutation. The study design revealed differences in performance between the two tested technologies for all four mutations. In conclusion, we successfully established a blueprint for a test procedure capable of verifying and validating a liquid biopsy workflow from blood collection to the analytical result.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available