4.5 Article

Comparative assessment of ActiGraph data processing techniques for measuring sedentary behavior in adults with COPD

Journal

PHYSIOLOGICAL MEASUREMENT
Volume 42, Issue 8, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/1361-6579/ac18fe

Keywords

ActiGraphy; accelerometry; physical activity; activPAL; sitting

Funding

  1. National Institutes of Health (NIH) through a National Institute of Nursing Research (NINR) [R01NR016093]
  2. Active for Life
  3. NIH NINR [F31NR018784, T32NR016914]
  4. COPD

Ask authors/readers for more resources

This study examined different techniques for processing ActiGraph data in sedentary adults with COPD and found that the best technique was using vector magnitude data with LFE filter, 120 min non-wear algorithm, and <40 counts/15 s SB cut-point. The results suggest that these findings can guide future decisions on data processing for ActiGraph.
Objective. The ActiGraph is commonly used for measuring sedentary behavior (SB), but the best data processing technique is not established for sedentary adults with chronic illness. The purpose of this study was to process ActiGraph vertical axis and vector magnitude data with multiple combinations of filters, non-wear algorithm lengths, and cut-points and to compare ActiGraph estimates to activPAL-measured sedentary time in sedentary adults with chronic obstructive pulmonary disease (COPD). Approach. This study was a secondary analysis of adults >= 50 years (N = 59; mean age: 69.4 years; N = 31 males) with COPD. Participants wore ActiGraph GT9X and activPAL3 for 7 d. ActiGraph vertical axis and vector magnitude data were processed using combinations of filters (normal, low frequency extension (LFE)), non-wear algorithm lengths (60, 90, 120 min), and cut-points for SB previously validated in older adults (two for vertical axis and three for vector magnitude data). The Bland-Altman method was used to assess concordance between sedentary time measured with 30 ActiGraph techniques and activPAL-measured sedentary time. Main results. Agreement between the two devices was moderate to strong for all techniques; concordance correlations ranged from 0.614 to 0.838. Limits of agreement were wide. The best overall technique was vector magnitude data with LFE filter, 120 min non-wear algorithm, and <40 counts/15 s SB cut-point (concordance correlation 0.838; mean difference -11.7 min d(-1)). Significance. This analysis supports the use of ActiGraph vector magnitude data and LFE filter in adults with COPD, but also demonstrates that other techniques may be acceptable with appropriate cut-points. These results can guide ActiGraph data processing decisions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available