4.1 Review

Outcome of right ventricular assist device implantation following left ventricular assist device implantation: Systematic review and meta-analysis

Journal

PERFUSION-UK
Volume 37, Issue 8, Pages 773-784

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/02676591211024817

Keywords

left ventricular assist device; right ventricular assist device; right heart failure

Funding

  1. Naef Foundation, Lausanne

Ask authors/readers for more resources

This study systematically evaluated outcomes for patients undergoing RVAD implantation following LVAD implantation, finding that temporary RVAD implantation is associated with worse outcomes and biventricular mechanical circulatory support leads to higher mortality and incidence of adverse events compared to isolated LVAD support.
Objectives: The main aim was a systematic evaluation of the current evidence on outcomes for patients undergoing right ventricular assist device (RVAD) implantation following left ventricular assist device (LVAD) implantation. Methods: This systematic review was registered on PROSPERO (CRD42019130131). Reports evaluating in-hospital as well as follow-up outcome in LVAD and LVAD/RVAD implantation were identified through Ovid Medline, Web of Science and EMBASE. The primary endpoint was mortality at the hospital stay and at follow-up. Pooled incidence of defined endpoints was calculated by using random effects models. Results: A total of 35 retrospective studies that included 3260 patients were analyzed. 30 days mortality was in favour of isolated LVAD implantation 6.74% (1.98-11.5%) versus 31.9% (19.78-44.02%) p = 0.001 in LVAD with temporary need for RVAD. During the hospital stay the incidence of major bleeding was 18.7% (18.2-19.4%) versus 40.0% (36.3-48.8%) and stroke rate was 5.6% (5.4-5.8%) versus 20.9% (16.8-28.3%) and was in favour of isolated LVAD implantation. Mortality reported at short-term as well at long-term was 19.66% (CI 15.73-23.59%) and 33.90% (CI 8.84-59.96%) in LVAD respectively versus 45.35% (CI 35.31-55.4%) p <= 0.001 and 48.23% (CI 16.01-80.45%) p = 0.686 in LVAD/RVAD group respectively. Conclusion: Implantation of a temporary RVAD is allied with a worse outcome during the primary hospitalization and at follow-up. Compared to isolated LVAD support, biventricular mechanical circulatory support leads to an elevated mortality and higher incidence of adverse events such as bleeding and stroke.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended