4.7 Article

Miniature microplasma carbon optical emission spectrometry for detection of dissolved oxygen in water

Related references

Note: Only part of the references are listed.
Article Chemistry, Analytical

The application of antioxidant compounds to minimize matrix effects in flowing liquid anode atmospheric pressure glow discharge optical emission spectrometry

Monika Gorska et al.

Summary: Investigating the impact of antioxidant addition in FLA APGD OES to reduce matrix effects originating from concomitant elements lead to enhancing analyte signals by up to 4.5-fold, improving efficiency in analyte transport. The proposed approach proved suitable for analyses of simulated manganese steel and mineral water samples, with detection limits for Ag, Pb, and Zn ranging from 0.006 to 0.4 μg L-1 and excellent measurement precision and analyte recoveries.

MICROCHEMICAL JOURNAL (2021)

Article Chemistry, Analytical

A smartphone-based absorbance device extended to ultraviolet (365 nm) and near infrared (780 nm) regions using ratiometric fluorescence measurement

Xiaolan Chen et al.

Summary: A portable absorbance device with a wavelength range covering from ultraviolet to near-infrared regions was developed, expanding the applications of visualized colorimetric analysis. The device utilizes red-emitting carbon quantum dots as the detection fluorophore for determinations of folic acid, dissolved oxygen, and hypochlorous acid. The device offers advantages of portability, reliability, and accuracy for field analysis of dissolved oxygen in environmental water samples.

MICROCHEMICAL JOURNAL (2021)

Article Chemistry, Analytical

Determination of dissolved oxygen in water by the Winkler method: Performance modelling and optimisation for environmental analysis

Ariely Carvalho et al.

Summary: Dissolved oxygen concentration in water is a crucial parameter for assessing aquatic ecosystem health. Measurement uncertainty is important in determining the reliability of dissolved oxygen values, which can be calculated using electrochemical sensors or the reference Winkler method. The evaluation of performance and optimization of measurement uncertainty is essential for accurately differentiating dissolved oxygen values.

MICROCHEMICAL JOURNAL (2021)

Article Chemistry, Multidisciplinary

Automated Miniaturized Digital Microfluidic Antimicrobial Susceptibility Test Using a Chip-Integrated Optical Oxygen Sensor

Wenting Qiu et al.

Summary: A novel digital microfluidic platform with an optical oxygen sensor film was developed for real-time antimicrobial susceptibility testing, allowing for continuous monitoring of bacterial growth and accurate results comparable to the standard method. Automatic sample dispensation, dilution, and mixing were achieved on the chip within a short timeframe, demonstrating the potential for rapid and reliable analysis with minimal sample handling.

ACS SENSORS (2021)

Article Engineering, Chemical

POSS: A Morphology-Tuning Strategy To Improve the Sensitivity and Responsiveness of Dissolved Oxygen Sensor

Shuwen Wang et al.

INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH (2019)

Article Engineering, Environmental

Oxidation of Reduced Peat Particulate Organic Matter by Dissolved Oxygen: Quantification of Apparent Rate Constants in the Field

Nicolas Walpen et al.

ENVIRONMENTAL SCIENCE & TECHNOLOGY (2018)

Article Nanoscience & Nanotechnology

Phosphorescent Carbon Dots for Highly Efficient Oxygen Photosensitization and as Photo-oxidative Nanozymes

Jinyi Zhang et al.

ACS APPLIED MATERIALS & INTERFACES (2018)

Article Multidisciplinary Sciences

Decline in global oceanic oxygen content during the past five decades

Sunke Schmidtko et al.

NATURE (2017)

Article Chemistry, Physical

Self-Assembly of Peptide Nanostructures onto an Electrode Surface for Nonenzymatic Oxygen Sensing

Camila P. Sousa et al.

JOURNAL OF PHYSICAL CHEMISTRY C (2015)

Review Chemistry, Multidisciplinary

Biological detection by optical oxygen sensing

Dmitri B. Papkovsky et al.

CHEMICAL SOCIETY REVIEWS (2013)

Article Chemistry, Analytical

A highly accurate method for determination of dissolved oxygen: Gravimetric Winkler method

Irja Helm et al.

ANALYTICA CHIMICA ACTA (2012)

Article Chemistry, Analytical

Tracer Monitored Titrations: Measurement of Dissolved Oxygen

Todd Martz et al.

ANALYTICAL CHEMISTRY (2012)

Article Chemistry, Analytical

Efficient Fluorescence Turn-On Sensing of Dissolved Oxygen by Electrochemical Switching

Ik-Soo Shin et al.

ANALYTICAL CHEMISTRY (2012)

Review Instruments & Instrumentation

Chemical Vapor Generation with Slurry Sampling: A Review of Applications to Atomic and Mass Spectrometry

Henryk Matusiewicz et al.

APPLIED SPECTROSCOPY REVIEWS (2012)

Review Instruments & Instrumentation

Microplasma Technology and Its Applications in Analytical Chemistry

Xin Yuan et al.

APPLIED SPECTROSCOPY REVIEWS (2011)

Article Engineering, Environmental

Determination of Dissolved Oxygen in the Cryosphere: A Comprehensive Laboratory and Field Evaluation of Fiber Optic Sensors

E. A. Bagshaw et al.

ENVIRONMENTAL SCIENCE & TECHNOLOGY (2011)

Review Chemistry, Analytical

Dissolved oxygen in the bottom water of the Sea of Japan as a sensitive alarm for global climate change

Toshitaka Gamo

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2011)

Review Chemistry, Analytical

Applications of chemical vapor generation in non-tetrahydroborate media to analytical atomic spectrometry

Peng Wu et al.

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY (2010)

Review Chemistry, Analytical

Optical oxygen sensors move towards colorimetric determination

Xu-dong Wang et al.

TRAC-TRENDS IN ANALYTICAL CHEMISTRY (2010)

Article Chemistry, Analytical

Micro-Winkler titration method for dissolved oxygen concentration measurement

Irja Helm et al.

ANALYTICA CHIMICA ACTA (2009)