4.5 Article

A new optical coherence tomography method for subfoveal choroidal thickness measurement A single-center observational study

Journal

MEDICINE
Volume 100, Issue 24, Pages -

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000026355

Keywords

choroid; fovea; optical coherence tomography; retina

Funding

  1. National Research Foundation of Korea [NRF-2019R1G1A1011559]

Ask authors/readers for more resources

This study investigated a new method for measuring subfoveal choroidal thickness (SFCT) using optical coherence tomography, and found that this new method showed the lowest interpersonal variability and could be a reliable standard for SFCT measurement.
Several macular pathologies are associated with choroidal vascular supply and thus require choroidal thickness evaluation. However, there is no standard subfoveal choroidal thickness (SFCT) measurement method. This study investigated a new method of SFCT measurement, using optical coherence tomography. This is a single-center observational study. Eighty-two senior medical students participated as observers and independently measured the SFCT on 5 standard optical coherence tomography images of healthy adults in a tertiary care setting. They used 3 different methods: the observer's own method, the conventional method, perpendicular to the retinal pigment epithelium, and the new method, along a virtual line connecting the umbo with the most elevated point of the ellipsoid. Additionally, the SFCT angle-the angle between the measurement line and the vertical line of the image-was measured and compared between methods. The intraclass correlation coefficient was used to determine interpersonal variability. The intraclass correlation coefficients for SFCT, measured using methods 1, 2, and 3, were 0.853, 0.880, and 0.896, respectively (P < .001 for all). Method 3 was the highest. The intraclass correlation coefficients of the SFCT angles were 0.647, 0.842, and 0.307, respectively (P < .001 for all). The new method showed the lowest interpersonal variability and could therefore be a reliable standard for SFCT measurement, even in foveae with a steep slope on optical coherence tomography. Trial registration: Not applicable.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available