Fully automated treatment planning for MLC-based robotic radiotherapy

Journal

MEDICAL PHYSICS
Volume 48, Issue 8, Pages 4139-4147

Publisher

WILEY
DOI: 10.1002/mp.14993

Keywords

automated treatment planning; beam angle and beam profile optimization; BAO and IMRT; prostate SBRT; robotic CyberKnife (R) radiotherapy

Funding

  1. Accuray Inc., Sunnyvale, USA

Ask authors/readers for more resources

A fully automated multicriterial treatment planning solution for CyberKnife equipped with InCise(TM) 2 multileaf collimator was proposed and validated. The automated plans showed clinical acceptability and dosimetric similarity to reference plans, with reduced beam and segment numbers as well as delivery times. This new optimization workflow offers the potential for high-quality, deliverable plans with time and resource savings compared to manual planning.
Purpose: To propose and validate a fully automated multicriterial treatment planning solution for a CyberKnife (R) equipped with an InCise(TM) 2 multileaf collimator. Methods: The AUTO BAO plans are generated using fully automated prioritized multicriterial optimization (AUTO MCO) of pencil-beam fluence maps with integrated noncoplanar beam angle optimization (BAO), followed by MLC segment generation. Both the AUTO MCO and segmentation algorithms have been developed in-house. AUTO MCO generates for each patient a single, high-quality Pareto-optimal IMRT plan. The segmentation algorithm then accurately mimics the AUTO MCO 3D dose distribution, while considering all candidate beams simultaneously, rather than replicating the fluence maps. Pencil-beams, segment dose depositions, and final dose calculations are performed with a stand-alone version of the clinical dose calculation engine. For validation, AUTO BAO plans were generated for 33 prostate SBRT patients and compared to reference plans (REF) that were manually generated with the commercial treatment planning system (TPS), in absence of time pressure. REF plans were also compared to AUTO RB plans, for which fluence map optimization was performed for the beam angle configuration used in the REF plan, and the segmentation could use all these beams or only a subset, depending on the dosimetry. Results: AUTO BAO plans were clinically acceptable and dosimetrically similar to REF plans, but had on average reduced numbers of beams ((beams in AUTO BAO)/(beams in REF) (relative improvement): 24.7/48.3 (-49%)), segments (59.5/98.9 (-40%)), and delivery times (17.1/22.3 min. (-23%)). Dosimetry of AUTO RB and REF were also similar, but AUTO RB used on average fewer beams (38.0/48.3 (-21%)) and had on average shorter delivery times (18.6/22.3 min. (-17%)). Delivered Monitor Units (MU) were similar for all three planning approaches. Conclusions: A new, vendor-independent optimization workflow for fully automated generation of deliverable high-quality CyberKnife (R) plans was proposed, including BAO. Compared to manual planning with the commercial TPS, fraction delivery times were reduced by 5.3 min. (-23%) due to large reductions in beam and segment numbers. (c) 2021 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available