4.6 Article

Quantum Defects in Fluorescent Carbon Nanotubes for Sensing and Mechanistic Studies

Journal

JOURNAL OF PHYSICAL CHEMISTRY C
Volume 125, Issue 33, Pages 18341-18351

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.jpcc.1c05432

Keywords

-

Funding

  1. Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) [EXC 2033-390677874.RESOLV, EXC 2122-390833453]
  2. DFG
  3. VW foundation

Ask authors/readers for more resources

Single-wall carbon nanotubes can assemble with biopolymers to form highly sensitive biosensors, with their fluorescence changing when interacting with analytes. By exploiting quantum defects in the carbon lattice of SWCNTs, processes and rate constants involved in photophysical signal transduction have been identified. Additionally, the fluorescence response of SWCNTs is influenced by both their length and non-radiative rate constants.
Single-wall carbon nanotubes (SWCNT) fluoresce in the nearinfrared (NIR) region and have been assembled with biopolymers such as DNA to form highly sensitive molecular (bio)sensors. They change their fluorescence when they interact with analytes. Despite the progress in engineering these sensors, the underlying mechanisms are still not understood. Here, we identify processes and rate constants that explain the photophysical signal transduction by exploiting sp(3) quantum defects in the sp(2) carbon lattice of SWCNTs. As a model system, we use ssDNA-coated (6,5)-SWCNTs, which increase their NIR emission (E-11, 990 nm) up to +250% in response to the important neurotransmitter dopamine. In contrast, SWCNTs coated with DNA but with a low number of NO2-aryl sp(3) quantum defects decrease both their E-11 (-35%) and defect-related E-11* emission (-50%) at 1130 nm. Consequently, the interaction with the analyte does not change the radiative exciton decay pathway alone. Furthermore, the fluorescence response of pristine SWCNTs increases with SWCNT length, suggesting that exciton diffusion is affected. The quantum yield of pristine (6,5)-SWCNTs increases in response to the analyte from 0.6 to 1.3% and points to a change in non-radiative rate constants. These experimental results for dopamine and other analytes are explained by a Monte Carlo simulation of exciton diffusion, which supports a change in two non-radiative decay pathways together with an increase in exciton diffusion (three-rate constant model). The combination of such SWCNTs with defects and without defects enables the assembly of ratiometric biosensors with opposing responses at different wavelengths. In summary, we demonstrate how perturbation of a nanomaterial with quantum defects reveals the photophysical mechanism and reverses optical responses of biosensors.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available