4.0 Article

Implications of Virtual CBCT-Based Immediate Implant Planning for Maxillary and Mandibular First Molars

Journal

JOURNAL OF ORAL IMPLANTOLOGY
Volume 48, Issue 5, Pages 386-390

Publisher

ALLEN PRESS INC
DOI: 10.1563/aaid-joi-D-20-00397

Keywords

molar; dental implants; cone-beam computed tomography

Ask authors/readers for more resources

This study used CBCT technology to simulate virtual implant placement and investigate the dimensions of implants in the mandible and maxilla. The results showed that immediate implant placement of first molars, especially in the maxilla, requires stringent presurgical evaluation. Implants no wider than 6 mm placed into the interradicular septum may meet acceptable running room and alveolar plate thickness criteria if the jumping distance is grafted.
The purpose of his study was to investigate the projected ridge-implant dimensions derived from virtual superimposition of implants on intact first molars mimicking immediate implantation in the mandible (Md1) and maxilla (Mx1) using cone-beam computed tomography (CBCT). The CBCT records of 41 patients (19 males and 22 females) with Md1 or Mx1 were collected. Ten-millimeter-long cylindrical implants with different diameters were virtually positioned at prosthetically ideal angles into interradicular septum using CBCT software. Radiographic alveolar ridge height (ARH), alveolar ridge width (ARW), gap distance, and vertical distance from the implant platform to the alveolar crest were measured. Twenty Mx1s (48.8%) and 21 Md1s (51.2%) were included. The mean ARH values were 7.13 +/- 4.32 and 15.64 +/- 1.80 mm for Mx1 and Md1, respectively; 87.8% of mesiobuccal sites had gap distance of >2 mm when 6-mm-diameter implants were used. Increasing implant diameter from 6 to 9 mm decreased the percentage of sites with ARW > 2 mm from 80.5% to 41.5% buccally and from 86.4% to 26.8% lingually. The mean vertical distance from the implant platform to the alveolar crest was 1.41 +/- 1.09 mm buccally and 1.11 +/- 1.10 mm lingually. Immediate implant placement of first molars, especially in the maxilla, requires stringent presurgical evaluation. Implants no wider than 6 mm placed into the interradicular septum may meet acceptable running room and alveolar plate thickness criteria if the jumping distance is grafted. Further clinical trials are needed to confirm these findings in this virtual study

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available