4.4 Article

Transradial cerebral angiography becomes more efficient than transfemoral angiography: lessons from 500 consecutive angiograms

Journal

JOURNAL OF NEUROINTERVENTIONAL SURGERY
Volume 14, Issue 4, Pages 397-402

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/neurintsurg-2021-017391

Keywords

angiography; aneurysm; artery; catheter; technique

Ask authors/readers for more resources

During the first full year of radial-first implementation, 86.2% of 500 consecutive angiograms were successfully performed using TRA. TRA efficiency exceeded that of TFA after 150 angiograms. Concerns about procedure length or radiation exposure should not be barriers to TRA adoption.
Background Transradial arterial access (TRA) for cerebral diagnostic angiography is associated with fewer access site complications than transfemoral access (TFA). However, concerns about increased procedure time and radiation exposure with TRA may slow its adoption. Our objective was to measure TRA rates of success and fluoroscopy time per vessel after 'radial-first' adoption and to compare these rates to those obtained with TFA. Methods We examined 500 consecutive cerebral angiograms on an intent-to-treat basis during the first full year of radial-first adoption, recording patient and procedural characteristics and outcomes. Results Over a 9-month period at a single center, 457 of 500 angiograms (91.4%) were performed with intent-to-treat via TRA, and 431 cases (86.2%) were ultimately performed via TRA. One patient (0.2%) experienced a temporary neurologic deficit in the TRA group, and none (0%) did in the TFA group (p=0.80). The mean +/- SD fluoroscopy time per vessel decreased significantly from the first half of the study to the second half for TRA (5.0 +/- 3.8 vs 3.4 +/- 3.5 min/vessel; p<0.001), while TFA time remained unchanged (3.7 +/- 1.8 vs 3.5 +/- 1.4 min/vessel; p=0.69). The median fluoroscopy time per vessel for TRA became faster than that for TFA after 150 angiograms. Conclusion Of 500 consecutive angiograms performed during the first full year of radial-first implementation, 86.2% were performed successfully using TRA. TRA efficiency exceeded that of TFA after 150 angiograms. Concerns about the length of procedure or radiation exposure should not be barriers to TRA adoption.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available