4.0 Article

Higher than recommended lesion size index target values for pulmonary vein isolation result in better clinical outcomes in paroxysmal atrial fibrillation patients

Journal

Publisher

SPRINGER
DOI: 10.1007/s10840-021-01053-4

Keywords

Lesion size index; Lesion transmurality; Radiofrequency catheter ablation; Paroxysmal atrial fibrillation

Ask authors/readers for more resources

The study showed that higher and targeted lesion size index on different segments of pulmonary veins during ablation could lead to better clinical outcomes for paroxysmal atrial fibrillation without harmful effects.
Purpose Catheter ablation is a cornerstone of the therapy for paroxysmal atrial fibrillation. The importance of effective lesion size formation during pulmonary vein isolation is gauged through conduction recovery and recurrence of arrhythmia. Therefore, the lesion size index (LSI) is designed to utilize traditional intraprocedural parameters and predict procedural success. The impact of the optimal LSI index and the respective segments of the pulmonary veins has not been commonly evaluated. We aimed to assess whether higher and targeted LSI on the different segments of pulmonary veins could actually lead to better clinical outcomes of paroxysmal atrial fibrillation ablation. Methods Retrospective analyses of drug-refractory paroxysmal atrial fibrillation patients who underwent first catheter ablation were conducted. Targeted LSI of 6.5 at the anterior wall and 5.2 at the posterior wall, roof, and floor of the pulmonary vein was applied. The primary endpoint was defined as arrhythmias recurrence assessed by routine electrocardiograms and 24-h ambulatory electrocardiographic monitoring at 3, 6, and 12 months post-ablation. Results Among the included 39 patients, the single-procedure 12-month freedom from arrhythmias was reached in 92.3% of patients. Interestingly, there was no tendency towards an increased number of adverse effects using a higher LSI index. Conclusions Atrial fibrillation ablation guided by targeted LSI value showed efficiency on the freedom from arrhythmias during 1-year follow-up period without harmful effects.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available