4.5 Article

Measurements of isobaric heat capacities for HFE-7000 and HFE-7100 at different temperatures and pressures

Journal

FLUID PHASE EQUILIBRIA
Volume 425, Issue -, Pages 335-341

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.fluid.2016.06.024

Keywords

Flow calorimeter; HFE-7000; HFE-7100; Heat capacity

Funding

  1. scientific research project - Xi'an Aeronautical University [2016KY1205]

Ask authors/readers for more resources

This paper presents the heat capacities of HFE-7000 and HFE-7100 by a flow calorimeter. Ethanol has been used as a reference fluid to validate the flow calorimeter at different pressures and temperatures. With the flow calorimeter, the isobaric heat capacity of HFE-7000 (1-methoxyheptafluoropropane) and HFE-7100 (methoxy-nonafluorobutane) were measured in the temperature range from (255-294) K and from (255-323) K, respectively, and pressures up to 15 MPa. Through measuring the heat capacity of ethanol, the combined expanded uncertainty with a level of confidence of 0.95 (k = 2) of the measurement was estimated to less than +/- 2%. The measured heat capacity values of HFE-7000 and HFE-7100 were correlated by the Garg equation. The calculated values showed good agreement with the experimental values. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available