4.7 Article

Thermodynamic, economic, and environmental analysis of a novel hybrid energy storage system: Psuedo-dynamic modeling approach

Journal

INTERNATIONAL JOURNAL OF ENERGY RESEARCH
Volume 45, Issue 14, Pages 20016-20036

Publisher

WILEY-HINDAWI
DOI: 10.1002/er.7077

Keywords

dynamic operation analysis; economic analysis; environmental analysis; high-temperature heat and power storage; off-design condition; thermodynamic analysis

Ask authors/readers for more resources

The combination of high-temperature heat and power storage with an organic Rankine cycle is a clever measure for addressing the low electrical efficiency issue, leading to higher overall system efficiency. The thorough feasibility study conducted in this article provides insights into the technical, environmental, and economic performance aspects of the hybrid energy storage solution under dynamic operating conditions.
High-temperature heat and power storage is a promising recent proposed energy storage technology, just suffering from low electrical efficiency. The combination of this system with an organic Rankine cycle can be a very clever measure for addressing this drawback of the technology and achieving higher electrical efficiency. The present article presents a very thorough feasibility study on this innovative hybrid energy storage solution digging into its thermodynamic performance proficiency, cost-effectiveness, environmental effectiveness, and, more importantly, the effects of partial load operation on its techno-economic indices. For the latter, the effects of load variations on the mass flow rate, pressure ratio, and isentropic efficiency of the turbomachinery are considered to give the most accurate possible picture of the technical, environmental, and economic performance aspects of the system in dynamic operating conditions. In addition to a concrete answer regarding the feasibility of the technology, the further findings of the article would be strongly beneficial for finding the optimal performance of the storage technology when working in a renewable power plant with ups and downs in power outputs. As the results show, the annual averaged electrical efficiencies of the system is 27.07/43.01% with/without considering the impact of the dynamic condition. The levelized cost of storage of the system will be 621.5 euro/MWh and 390 euro/MWh, when considering and not considering the impacts of the partial load operations, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available