Impact of vascular morphology and plaque characteristics on computed tomography derived fractional flow reserve in early stage coronary artery disease

Journal

INTERNATIONAL JOURNAL OF CARDIOLOGY
Volume 343, Issue -, Pages -

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijcard.2021.08.036

Keywords

Coronary computed tomography angiography; Fractional flow reserve; Atherosclerosis; Plaque; Overestimation

Ask authors/readers for more resources

This study examined predictive factors for FFRCT decrease to below 0.80 in vessels without apparent coronary artery disease, finding that the presence of intermediate-attenuation plaque (IAP) volume was the strongest predictor of this decline. Vessel morphology and plaque characteristics should be considered when interpreting FFRCT results.
Background: Computed-tomography (CT) derived fractional-flow-reserve (FFRCT) gradually may decrease from proximal to distal vessels even without apparent coronary artery disease (CAD). It may be unclear whether the decrease in FFRCT at the distal coronal artery is physiological or due to stenosis. We decided to study predictive factors of an FFRCT decline below the pathological value of 0.80 in no-apparent CAD. Methods: A total of 150 consecutive patients who had both CT angiography coupled to FFRCT analysis and invasive angiogram showing < 20% coronary stenosis were included. Vessels were divided into two groups according to FFRCT at the distal vessel: FFRCT > 0.80 (n = 317) and FFRCT <= 0.80 (n = 114). Delta FFRCT was defined as the change in FFRCT from proximal to distal vessel. Vessel morphology (vessel length and lumen volume) and plaque characteristics [low-attenuation plaque volume, intermediate-attenuation (IAP) plaque volume, and calcified plaque volume] were evaluated. Results: FFRCT decreased from proximal to distal for the three major vessels in both FFRCT > 0.80 and FFRCT <= 0.80. Compared to FFRCT > 0.80, IAP volume was significantly higher in all three major vessels in FFRCT <= 0.80. Delta FFRCT was correlated with vessel length and lumen volume in FFRCT > 0.80, whereas Delta FFRCT was correlated with IAP volume in FFRCT <= 0.80. IAP volume above 44.8 mm(3) was the strongest predictor of distal FFRCT of <= 0.80. Conclusions: The presence of IAP is a major predictor of gradual decrease of FFRCT below 0.80 in no-apparent CAD vessels. Vessel morphology and plaque characteristics should be considered when interpreting FFRCT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available