4.7 Article

Robust Heart Rate Monitoring by a Single Wrist-Worn Accelerometer Based on Signal Decomposition

Journal

IEEE SENSORS JOURNAL
Volume 21, Issue 14, Pages 15962-15971

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2021.3075109

Keywords

Accelerometers; heart rate; motion artifacts; singular spectrum analysis; Kalman smoothing; wearable sensors

Funding

  1. National Natural Science Foundation of China [21635001]
  2. State Key Project of Research and Development [2016YFF0100802]
  3. Open Research Fund of State Key Laboratory of Bioelectronics, Southeast University

Ask authors/readers for more resources

The study demonstrated a wrist-worn heart rate monitor using a single accelerometer, with signal decomposition algorithms and Kalman smoothing to remove motion artifacts and noise, providing more accurate heart rate estimation within +/- 8.86 bpm, longer battery life and better wearing comfort compared to PPG.
Monitoring heart rate (HR) by a single wristworn accelerometer would provide many advantages over electrocardiogram (ECG) or photoplethysmography (PPG), such as wearing comfortability, saving power, tiny footprint and automatic motion artifact removal. However, like ECG, accelerometry was mostly implemented on the chest, named seismocardiogram (SCG), and PPG was dominating the wrist worn format. Pulse condition detection in Traditional Chinese Medicine or sphygmography was engineered into a wearable format in this work, and a wrist-worn HR monitor by a single accelerometer was demonstrated. A major limitation of wristworn device is that motion artifacts and noise severely corrupt the signal integrity. In this study, with raw data segments including hundreds of random finger or hand motions, several signal decomposition algorithms were compared, such as independent component analysis (ICA), variable mode decomposition (VMD), wavelet synchrosqueezed transform (WSST), and singular spectrum analysis (SSA), and Kalman smoothing was implemented to track HR continuously. Our method was tested on 20 subjects during random finger tapping or hand swinging. Without knowing properties of noise or motion beforehand or requirement of an extra sensor as reference, our method provides a significant removal of motion artifacts and noise from three-dimensional acceleration signals, with 95% of HR estimation within +/- 8.86 bpm, much longer battery life and better wearing comfort than PPG. It would broaden the working conditions, and thus provide a more holistic assessment of HR during everyday life.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available