4.7 Article

A Novel Two Degrees of Freedom System for Measuring Iron Ore Water Content on a Conveyor Belt

Journal

IEEE SENSORS JOURNAL
Volume 21, Issue 14, Pages 16291-16300

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2021.3076428

Keywords

Complex impedance; iron ore; moisture; real-dual frequency method, and relative dielectric constant

Funding

  1. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES), Brazil [001]
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)
  3. Instituto Tecnologico Vale (ITV)
  4. Universidade Federal de Ouro Preto (UFOP)

Ask authors/readers for more resources

This paper presents a system for measuring iron ore moisture on a conveyor belt, which has vertical and parallel movement capabilities, allowing real-time and in situ measurements. The system uses the capacitive method to determine the dielectric constant of the iron ore for moisture measurement.
Water content or moisture of materials is a parameter widely used in the industry. In mining, it is an important variable to control in iron ore production. High moistures may cause instability of iron ore piles and may make transport by ship unfeasible. Therefore, this paper presents the development of a system for measuring iron ore moisture on a conveyor belt (laboratory-scale). The structure that supports the sensor has two degrees of freedom, which allow perpendicular and parallel movements. The parallel movement makes the relative velocity between the measurement cell and the ore almost zero. The vertical movement allows the sensor to be placed at different depths in the ore. These sets enable real-time and in situ measurements. The system uses the capacitive method to determine the dielectric constant of the iron ore located between the sensor electrodes and, consequently, the moisture. This system has a measuring range of 0 to 14% on a dry basis and presents an uncertainty up to 0.07 percentage points for a 2-standard-deviation confidence level. In the validation process, the absolute error was less than 0.34 percentage point in the mining interest range of 6 to 14%. The founded results achieve a significant advance in the development of real-time equipment for measuring ore moisture since there is no device capable of doing it with the necessary level of accuracy and precision. For mining, this kind of system represents a big step to take corrective and preventive decisions around iron ore moisture control.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available