In this study, a novel electrochemical cytosensor was developed for sensitive detection and quantification of KG1a cells as a model of leukemia stem cells, based on the overexpression of cell surface protein CD123. The sensor showed high sensitivity and selectivity, with a remarkable linear detection range and limit of detection. The versatile and accurate nature of the cytosensor was further validated using clinical samples, showcasing its potential as a next generation sensor for early detection of leukemia stem cells.
Leukemia stem cells (LSCs) are suitable candidates to be deployed for the diagnosis and therapy of acute myeloid leukemia (AML) patients. In this study, a novel electrochemical cytosensor was designed for the sensitive detection and quantification of KG1a cells as a model of LSCs. The developed cytosensor was based on the overexpression of cell surface protein CD123 by leukemia KG1a cells. For this purpose, the glassy carbon electrode was modified by graphene quantum dots (GQDs), Au nanoparticles, streptavidin coated AuNPs, biotinylated CD123 antibody and target cells. The dense loading of CD123 antibody and electrical enhancement on the modified electrode were carried out using GQDs, this resulting in a sensitive detection of CD123 positive cells within KG1a cells. Step by step preparation of the nanomaterial-based cytosensor and its optimization steps were confirmed by different electrochemical techniques. The field emission scanning electron microscopy (FE-SEM) images also confirmed the proper attachment of the materials and the cells on the surface of the modified electrode. The linear detection range (LDR) and limit of detection (LOD) of the developed electrochemical biosensor were recorded as 1 cell/mL and 1-25 cells/mL, respectively, which is remarkable. Importantly, the present findings are precise and highly selective in the presence of other leukemia cells (NB4, HL60, and U937 cells). Further, the versatility and accuracy of the proposed cytosensor were evaluated using clinical samples. We believe that the cytosensor proposed in this study has the potential to serve as a next generation sensor for the early detection of leukemia stem cells.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available